background image

CPE...-PRS...

Festo CPE...-PRS 2017-12f English

8

If using 

cone-shaped

 QS..-... plug connectors:

Warning

S

 Make sure that the connecting threads
are not screwed in fully.

Otherwise the thread will be damaged.

S

Screw the connectors into the ports with 

two

 layers of sealing tape as follows:

– at first by hand
– then two turns more with a suitable  tool.

For closing non-required valve locations:

S

Use blind plates 

3

 (see Fig. 1) of type CPE-...-PRSB.

5

Maintenance and care

S

Clean the CPE...-PRS... when required with the cleaning agents specified.

– water or soap suds (max. 60 °C)
– petroleum ether (free of aromatic compounds).

6

Dismantling and repairs

In order to dismantle the CPE valves:

S

Exhaust the CPE...-PRS...

S

Pull the valve slide 

2

 outwards one notch.

Observe here the minimum distance between the valve slide and the mounting
surface of the connector 

1

.

Fig. 11

Содержание CPE-10-PRS series

Страница 1: ...en Operating instructions 8080201 2017 12f 8080203 Manifold block CPE PRS ...

Страница 2: ...slation of the original instructions Symbols Installation and commissioning may only be per formed in accordance with these instructions by technicians with appropriate qualifications Warning Caution Note Environment Accessories English 3 ...

Страница 3: ... For all available product documentation è www festo com pk English Manifold block for valve linking module Type CPE PRS 1 Operating parts and connections 1 2 3 4 5 1 Connector 2 Valve slides 3 Blind plates 4 Protection against incorrect rotation 5 Fastening slides Fig 1 ...

Страница 4: ...2 valves with compressed air supply on one side or for each pressure zone with compressed air supply on two sides Fig 2 The diaphragms have been removed from the variants CPE PRSO Valve sub base CPE PRS is intended for mounting on a wall or on a hat rail 3 Safety conditions Note Incorrect handling can lead to malfunctioning For correct and safe use of the product S Compare the specified limit valu...

Страница 5: ... drawing a sketch If several pressure zones are used Note S Make sure that the diaphragms are not broken at the interface of two pres sure zones Damaged diaphragms cannot be sealed again You must decide here whether diaphragms should be removed from the compressed air channels in order to provide an unhindered flow Removing non required diaphragms S Proceed as follows Press the three diaphragms in...

Страница 6: ...ail until it engages è Fig 6 In order to fit the CPE valves Fig 7 1 Press in all the valve slides 2 until they snap into the first notch 2 Push a seal onto each compresssed air output 3 Screw the valve connectors with the seals fitted into connections 3 and 5 of the CPE valve 4 Place CPE valves onto the manifold block observe protection against torsion 4 press it on and simultaneously insert valve...

Страница 7: ...PE PRS to the hat rail Fastening onto a wall S Insert the following number of screws for fastening Component Number of screws required Sub base 2 Extension plate 1 End plate 2 Fig 10 Pneumatic S Use preferably round connectors of type QS with cylindrical connecting thread S Connect the pneumatic tubing in accordance with the pressurization sketch compare with Fig 3 The connecting threads must be s...

Страница 8: ...with a suitable tool For closing non required valve locations S Use blind plates 3 see Fig 1 of type CPE PRSB 5 Maintenance and care S Clean the CPE PRS when required with the cleaning agents specified water or soap suds max 60 C petroleum ether free of aromatic compounds 6 Dismantling and repairs In order to dismantle the CPE valves S Exhaust the CPE PRS S Pull the valve slide 2 outwards one notc...

Страница 9: ...away from the sub base 3 Dismantle the individual parts in the reverse order to fitting Dismantling from a hat rail 1 Remove the CPE valves 2 Loosen the locking screws 3 Dismantle linked CPE PRS 4 Use a screwdriver to lift up the fastening slides of the individual sub bases 7 Accessories Designation Type Blind plate CPE PRSB Designation signs IBS 6 x 10 Fig 13 Fig 12 5 ...

Страница 10: ...lve slide and valve must be flush Fig 14 9 Technical specifications Type CPE 10 PRS CPE 14 PRS CPE 18 PRS CPE 24 PRS Design Pneumatic sub base Fitting position As desired Medium Compressed air to ISO 8573 1 2010 7 4 4 Lubricated operation possible required during subsequent operation Permissible operating pressure 0 9 bar max 10 bar Max perm tightening torque for cylindrical connectors 6 Nm 8 Nm 3...

Страница 11: ...CPE PRS Festo CPE PRS 2017 12f 11 ...

Страница 12: ...ization is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Straße 82 73734 Esslingen Germany Phone 49 711 347 0 Fax 49 711 347 2144 E mail service_international festo com Internet www festo com ...

Отзывы: