Output of holding brake [X6B]
CMMT-AS-
C2-11A-P3
C3-11A-P3
C5-11A-P3
Design
High-side switch
1)
Max. continuous out-
put current
[A]
1
1.3
Max. voltage drop from
+ 24 V input at connec-
tion [X9A] to brake out-
put at [X6B]
[V DC]
0.8
1
Max. permissible
inductive load
[H]
<
5
Protective functions
–
Short circuit to 0 V/PE
–
Overvoltage-proof to 60 V
2)
–
Thermal overload protection
Fault detection
Voltage at output despite brake having shut down
Diagnostics possible via:
–
Output SBA
–
Error message on device
1) The test pulses of the associated control input #SBC-A are mapped to the output subject to a switching delay.
2) Brake output also shuts down in the event of a fault if there is an overvoltage on the logic supply.
Tab. 24 Output of holding brake [X6B], 3-phase devices
Technical data
39