8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
157
There are two reference travel speeds. The higher search velocity (
speed_during_search_
for_switch
) is used to find the limit switch or the reference switch. Then, to exactly
determine the position of the switch edge, the system switches to crawl speed
(
speed_during_search_for_zero
).
If the drive should not be newly referenced but only the position set to a specified value,
the object
2030
h
(
set_position_absolute
) can be used.
: set_position_absolute on page 97.
The drive to the zero position under CANopen is normally not a
component of the reference travel. If all necessary variables are
know to the motor controller (e.g. because it already knows the
position of the zero pulse), no physical movement is performed.
This behaviour can be changed via the object
6510
h
_ F0
h
(
compatibility_control
see chapter 6.2), so that a run to zero is
always carried out.
8.2.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
607C
h
VAR
home_offset
INT32
rw
6098
h
VAR
homing_method
INT8
rw
6099
h
ARRAY
homing_speeds
UINT32
rw
609A
h
VAR
homing_acceleration
UINT32
rw
2045
h
VAR
homing_timeout
UINT16
rw
Affected objects from other chapters
Index
Object
Name
Type
Chapter
6040
h
VAR
controlword
UINT16
7.1.3 Controlword (control word)
6041
h
VAR
statusword
UINT16
7.1.5 Statuswords (status word)