7. Device control
Festo P.BE-CMMP-CO-SW-EN 0708NH
143
EXAMPLE
The above example shows which bits in the
controlword
need to be set in
order to enable the motor controller. Now the newly written condition
should be read out of the
statusword
:
Transition from
SWITCH_ON_DISABLED
to
OPERATION_ENABLE
:
1.)
Write condition transition 2 into the
controlword
.
2.)
Wait until the condition
READY_TO_SWITCH_ON
is displayed in the
statusword
.
Transition 2:
controlword = 0006
h
Wait until (statusword & 006F
h
) = 0021
h
*1)
3.)
Transitions 3 and 4 can be written together
into the
controlword
.
4.)
Wait until the condition
OPERATION_ENABLE
is displayed in the
statusword
.
Transition
3+4
:
controlword = 000F
h
Wait until (statusword & 006F
h
) = 0027
h
*1)
Note:
The example assumes that no other bits are set in the
controlword
(for the transitions, only bits 0
…
3 are important).
*
1)
To identify the conditions, bits that are not set must also be
evaluated (see table). For that reason, the
statusword
must be masked
accordingly.
7.1.5
Statuswords (status word)
Object 6041
h
: statusword
Index
6041
h
Name
statusword
Object code
VAR
Data Type
UINT16
Access
ro
PDO Mapping
yes
Units
--
Value Range
--
Default Value
--