6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
101
6.9
Encoder adjustments
6.9.1
Overview
This chapter describes configuration of the angle encoder input X2A, X2B and the
incremental input X10.
Caution
Incorrect angle encoder settings can result in the drive turning
uncontrolledly and possibly destroy parts of the system.
6.9.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
2024
h
RECORD
encoder_x2a_data_field
ro
2024
h
_01
h
VAR
encoder_x2a_resolution
UINT32
ro
2024
h
_02
h
VAR
encoder_x2a_numerator
INT16
rw
2024
h
_03
h
VAR
encoder_x2a_divisor
INT16
rw
2025
h
RECORD
encoder_x10_data_field
ro
2025
h
_01
h
VAR
encoder_x10_resolution
UINT32
rw
2025
h
_02
h
VAR
encoder_x10_numerator
INT16
rw
2025
h
_03
h
VAR
encoder_x10_divisor
INT16
rw
2025
h
_04
h
VAR
encoder_x10_counter
UINT32
ro
2026
h
RECORD
encoder_x2b_data_field
ro
2026
h
_01
h
VAR
encoder_x2b_resolution
UINT32
rw
2026
h
_02
h
VAR
encoder_x2b_numerator
INT16
rw
2026
h
_03
h
VAR
encoder_x2b_divisor
INT16
rw
2026
h
_04
h
VAR
encoder_x2b_counter
UINT32
ro
Object 2024
h
: encoder_x2a_data_field
The record
encoder_x2a_data_field
collects parameters necessary for operation of the
angle encoder at plug X2A.
Since numerous angle encoder settings are effective only after a reset, selection and
setting of the encoders should be made via the parameterisation software. Under
CANopen, the following settings can be read out or changed:
The object
encoder_x2a_resolution
specifies how many increments are generated by the
encoder per revolution or length unit. Since at the input X2A only resolvers can be
connected which are always evaluated with 16 bit, 65536 is always returned here.