4. Connect valves at the rear using socket head screws and square nuts. Tightening torque:
1.2 ± 0.2 Nm
è
Fig. 4 Fitting, valve rear side
7.1.2
Creating Pressure Zones
In the case of pressure zone separation, connect the compressed air supply to both ends of the valve
manifold.
For pressure zone separation, the plug screw can be left in duct (1) of the valve. Plug screws for duct
(1) can also be ordered as accessories (VAME-P18-BP-G18-P5)
è
1. Screw the plug screw into the duct (1) of the selected valve
è
Fig.5. Screw in the plug screw until
it is flush with the surrounding surface.
Fig. 5 Plug screw
Mounting
7