![Festo 1548004 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/festo/1548004/1548004_repair-instructions_2283067035.webp)
35 / 55
Festo 7DFPIb_en
1. Plug the plug connector into the controller.
The colours of the individual wires in the cable harness are as follows from
top to bottom (end cap facing downwards):
Brown
White
Blue
Black
Grey
The wiring harness plug is protected against incorrect polarity and can only
be inserted in one direction. When inserted correctly, the pin contacts of the
plug will be facing inwards, and will not be visible from the outside.
2. Insert the controller into the end cap module so that the labels "OPEN",
"ERROR", "CLOSED" and "POWER" can be read from the outside.
3.
Screw in the mounting screws to a tightening torque of 0.8 Nm.
4. Plug the valve cable assembly into the valve block in accordance with the
labels "Y1", "Y2", "Y3" and "Y4".
4.5.4
Replacing the valve block
The valve block, controller and electronic function module make up the control unit of the linear actuator. The four
individual valves form a single unit together with the valve base, and move the linear actuator to the required travel
position. This enables additional travel to intermediate positions within the travel range.
The valve cable assembly and the connections on the valve block are numbered.
If the numbers are no longer legible, mark the pilot lines before detaching them from the valve block.
When connecting, make sure that the numbers on the pilot lines match the numbers of the connections on the valve
block.