ELECTRODE MAINTENANCE

GARMENT CLEANING

DO

Before donning the device, carefully sepa

-

rate the plastic protecting the gel.

Keep the protective layer to store the elec

-

trode at the end of its use.

DON'T

After  using  the  electrode,  spray  it  with  a 

few drops of water, letting it dry at air or 

with a cotton gauze.

Hydrate the electrode and reposition the  

protective plastic.

In  cases  of  excessive  sweating,  dry  the 

electrode with a cotton gauze. 

Change the electrode every 15 sessions.

It is important to respect the time of use 

of  the  electrodes  in  order  to  avoid  skin 

irritation.

Check the electrodes visually at the end 

of the session and regularly.

Store the electrodes in the original pac

-

kaging and close it with zip or tape for its 

correct conservation.

Do not place the device with the protec

-

tive plastic.

Do  not  throw  the  protective  plastic  in 

the trash.

Do  not  pour  too  much  water  on  the 

electrode.

In  case  of  excessive  sweating,  do  not 

moisturize the electrode.

Do not use the electrode for more than 

15 sessions.

Do  not  to  extend  the  life  of  the  elec

-

trodes using products not approved by 

Fesia

, such as gels of other types of de

-

vices.

Do not use the electrodes if the catho

-

des  are  blackened  (even  if  the  15  ses

-

sions have not been exceeded). Replace 

them.

Do  not  leave  the  electrode  without  a 

bag directly in the case or a bag other 

than the original one.

Maintenance

Clean with a damp cloth on both sides and disinfect in a 1% hydrogen peroxide solution for up to 5 minutes. 

Deep cleaning

Immerse in hot water (max. 40 ºC) using a large container without bending the garment. 

Rub with a soft cloth and dry at air.

Disinfection

To disinfect it, immerse in a 1% hydrogen peroxide solution for 5 minutes. If possible, use a UV device to disinfect the 

surface. Make sure to place it on both sides. Regarding the drying time, check with the supplier of the UV equipment.

Hand wash with a soft cloth on both sides.

Do not iron.

Do not use bleach.

Do not use the dryer.

MAINTENANCE 

05

05 

MAINTENANCE

Содержание Grasp

Страница 1: ...INSTRUCTIONS FOR USE FESIA GRASP FESIA FG01 IFU VER5 1 EN 2022 04...

Страница 2: ...ANUFACTURER Fesia Technology S L P Mikeletegi 58 20009 Donostia San Sebasti n Spain COMERCIALIZED BY Fesia Technology S L P Mikeletegi 58 20009 Donostia San Sebasti n Spain E MAIL support fesia net WE...

Страница 3: ...RMATION 8 11 Indications of use Legend Symbols FESIA GRASP DEVICE 14 23 General description Indicators Initial checks Device placement Device removal FESIA PRO APPLICATION 26 45 General description In...

Страница 4: ...GENERAL INFORMATION 01...

Страница 5: ...Must not be used near flammable products Store the device under protection from humidity dust and direct sunlight Use only the electrodes supplied by Fesia Use only the charger and charging cable sup...

Страница 6: ...This product should not be disposed with other household products Low battery red light Stimulation is active yellow light Intensity increase button Intensity reduction button On off button LEGEND Thi...

Страница 7: ...FESIA GRASP DEVICE 02...

Страница 8: ...ted to the skin through the multi field electrode 4 Fesia Pro app already installed in pre configured tablets provided by Fesia The device has a software application that allows on the one hand to con...

Страница 9: ...ator Ba ery indicator On o bu on Bluetooth indicator Reduce intensity bu on Increase intensity bu on S mula on on S mula on o S mulator on S mulator o Adequate ba ery level Low ba ery level S mula on...

Страница 10: ...SIA GRASP DEVICE 02 02 FESIA GRASP DEVICE INSTRUCTIONS FOR USE Fesia Grasp 19 18 INSTRUCTIONS FOR USE Fesia Grasp INITIAL CHECKS FULLY CHARGED Before the first use the device must be fully charged Thi...

Страница 11: ...until it clicks and make sure it is properly inserted Make sure the hand remains completely free 5 6 R R Place the electrode and garment on the forearm The ulnar diaphysis should be aligned with the...

Страница 12: ...provided respecting environmental conditions described in chapter 5 6 At the end of life of this device follow local regulations and never dis pose the product or batteries with normal household waste...

Страница 13: ...FESIA PRO APP 03...

Страница 14: ...that the later ality has been selected correctly After filling in the required data click on the Save button Search for the application in the Google Play Store by typing Fesia Pro in the search field...

Страница 15: ...ails The mandatory fields are indicated with an asterisk Make sure the chosen laterality is co rrect The affected limb must be cho sen that is the side where the device is going to be placed See patie...

Страница 16: ...nd the evolution chart Session data can be exported to an excel document by clicking on the Export button Grasp To access the protocols select the Grasp icon in the navigation menu There the user can...

Страница 17: ...n asterisk are the optimal candi dates to achieve a motor response in the movement that is being configured Non activated cathode Activated cathode Blocked cathode CLICK CLICK LONG TOUCH By doing a lo...

Страница 18: ...bjectives It can be used to increase maintain range of motion prevent muscle atrophy etc 3 In patients whose motor threshold is above the pain threshold This protocol can be used to lower the motor th...

Страница 19: ...ation parameters CONFIGURATION BAR Intensity edition Select the desired configuration and stimulation time Select configuration Select the desired movement Flexion Exten sion Select movement Start Sto...

Страница 20: ...R Stimulation parameters Select the configuration to load By default ex cept for the first time the last configuration made for that patient will be loaded Press Play to start the stimulation The conf...

Страница 21: ...on the options Complex 1 Complex 2 and Complex 3 To change the title and image of this movement make a long touch on the title In case of choosing predefined complex movements Open hand Grip Palm gri...

Страница 22: ...ull screen in the selected order There are 3 phases 1 Preparation A 3 second countdown and a dynam ic image of the movement to be performed are shown 2 Realization A descriptive static image of the mo...

Страница 23: ...king on the same image Select the next move clicking on the image of this TOGGLE KEYPAD The Toogle keypad acts as a button and trigger for stimulation By clicking directly on the image of the desired...

Страница 24: ...TECHNICAL SUPPORT 04...

Страница 25: ...the tablet screen Please try again if the error persists after restarting the device and tablet contact Fesia Support with the exact error message Make sure you have checked the following steps before...

Страница 26: ...f the arm is cone shaped Cmin Cmax 0 7 CHOOSE THE M L SIZE INSTRUCTIONS FOR USE Fesia Grasp 51 50 INSTRUCTIONS FOR USE Fesia Grasp SIZE SELECTION GUIDE If after choosing the S M size the textile does...

Страница 27: ...MAINTENANCE 05...

Страница 28: ...h Do not pour too much water on the electrode In case of excessive sweating do not moisturize the electrode Do not use the electrode for more than 15 sessions Do not to extend the life of the elec tro...

Страница 29: ...er is broken This can be due to Scratching the skin too hard Placing the electrode over a cut rash spot or insect bite Shaving the skin using a razor Using old dried out damaged or dirty electrodes Ve...

Страница 30: ...TECHNICAL INFORMATION 06...

Страница 31: ...intensity 0 60mA 1mA resolution for loads 5000 Pulse width 150us 300 us resolution of 5us Pulse frequency 1 40Hz resolution of 1 Hz Maximum output voltage 180V Maximum output frequency 1KHz PARAMETER...

Страница 32: ...nic emissions IEC 61000 3 2 Voltage fluctuations Flickers emis sions IEC 61000 3 3 Class B Class A Fulfill The device is suitable for use in establishments other than domestic and those directly conne...

Страница 33: ...te 1 Ut is the AC mains voltage prior to application of the test level Note 2 At 80 MHz and 800 MHz the higher frequency range applies Note 3 These guidelines may not apply in all situations Electroma...

Отзывы: