1.2 Technical specifications

1) Resolution: 0.01 mm
2) Repeatability: 0.01 mm
3) Accuracy: ±(0.02+0.00005 x L). ”L” is the length measured in millimetres.
4) Maximum speed of measurement: 1m/s
5) Power: SR44 cell battery, 1.55 V.

1.3 Applications

1) Keep the measuring surface of the caliper clean, and all the contact parts.
2) Loosen the locking screw and move the cursor. Check if the screen and the buttons are

working properly.

3) Adjust the starting point of measurement:

The closed measurement jaws are usually taken as the absolute zero point for external
measurements (without the characters "INC" displayed on the screen, the displayed value

must be zero, otherwise repeat the adjustment. When measuring the diameter of a hole, the
value of "K" has to be inserted. If the preset value is zero, the measurement plus "K" is the

diameter of the hole. If you frequently measure the diameter of holes, insert the value "K" as

the preset value. See paragraph 3 Operation Keys under the heading SET

4) Relative measurement:

To check the accuracy of pieces in series, measure the sample, press the ABS/zero button
(the screen is cleared and the word INC appears in the upper right corner), measure the

pieces, the screen will display the deviation between the sample and the measured piece

(negative measurement if the measured piece is smaller than the sample, positive
measurement if the measured piece is larger than the sample piece). Pressing the ABS/zero

button again will return the device to absolute measurement.

1.4 Battery replacement

When the screen flashes, or does not even turn on, open the cover and replace the battery.

If the battery purchased does not work satisfactorily, contact the supplier.

NB

1) The positive pole of the battery needs to facing upwards.
2) After replacing the battery it is necessary to repeat the adjustment of the starting point.

fervi.com

Содержание C043/500

Страница 1: ...USE AND MAINTENANCE MANUAL STAINLESS STEEL ELECTRONIC DIGITAL CALIPER Art C043 500 C043 1000 C047 500 TRANSLATION OF THE ORIGINAL INSTRUCTIONS f e r v i c o m ...

Страница 2: ...documentation cited and or attached It is expressly forbidden to reproduce publish or distribute any information from this Manual Copyright by FERVI Index 1 INSTRUCTIONS 4 1 1 Operation 4 1 1 1 Operation keys 5 1 1 2 Data output 5 1 2 Technical specifications 6 1 3 Applications 6 1 4 Battery replacement 6 f e r v i c o m ...

Страница 3: ...d in this manual Operator Qualification The operators assigned to using this instrument must be supplied with all of the necessary information and instruction and should be provided with adequate training regarding safety in pertaining to a The conditions of use of the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the Machine s conformi...

Страница 4: ...liper clean the surface of the protective adhesive using a clean dry cloth To remove condensation dirt use a cloth lightly dampened with ethyl alcohol 2 Conditions of use Temperature 5 40 C Relative humidity lower than 80 Prevent the protective adhesive from coming into contact with liquids containing water that can damage the circuit board 3 Do not apply voltage e g impact with an electric pen to...

Страница 5: ...o point by pressing the ABS zero button The measured value corresponds to the movement of the cursor from the relative zero point negative numbers to the left positive numbers to the right SET Pre adjustment button When pressing this button the preset value will be displayed The factory default value is zero Press the SET button and at the same time the or button at the top of the screen the lette...

Страница 6: ...ring the diameter of a hole the value of K has to be inserted If the preset value is zero the measurement plus K is the diameter of the hole If you frequently measure the diameter of holes insert the value K as the preset value See paragraph 3 Operation Keys under the heading SET 4 Relative measurement To check the accuracy of pieces in series measure the sample press the ABS zero button the scree...