1.1.1 Operation keys

ON/OFF: On and off switch

IN/mm: Inch / mm conversion key.

ABS/zero: Conversion key between absolute measurement / relative measurement.

Absolute measurement: This is performed when the characters "INC" are not displayed on the

screen. The closed measurement jaws, are usually taken as the starting point of the

measurement. For external measurements such as measuring the diameter of a tree, the
starting value must be zero. For internal measurements, such as a hole, the preset value

should be "K" mm/inch. The absolute value measured corresponds to the preset value, plus
the movement of the cursor from the starting point of relative measurement (positive

numbers to the right, negative numbers to the left.

Relative measurement: with the characters "INC" display on the screen. Set the zero point by

pressing the "ABS/zero" button. The measured value corresponds to the movement of the
cursor from the relative zero point (negative numbers to the left, positive numbers to the

right).
SET: Pre-adjustment button.

When pressing this button, the preset value will be displayed (The factory default value is
zero). Press the SET button and at the same time the

or

button, at the top of the screen

the letters "SET" will appear on the screen, the instrument is ready for the entry of the
absolute value. Press and hold down the

or

button, the numeric value will decrease or

increase when the desired value is displayed, release the button, press the "SET" button

again and the word "SET" will disappear from the screen. Presetting is performed.

1.1.2 Data output

The data can be transferred to a computer or compatible printer thanks to an optional

interface (ART I001)

Working method of the interface: synchronous series.

Data:

binary code, 24 bit. Each datum will be sent twice
The transmitting cycle is 300ms (20ms in fast reading state)
Transmitting time: 0.5 ms.

The four contacts (L -> R):

positive power supply (+); Data (D); Pulse frequency (CP);

negative power supply (-).

Pulse range of data:  

data level ≤ 0.2 V, level "1" ≥ 1.3 V. 

Pulse frequency CP:

90KHz, effective for high electrical levels.

fervi.com

Содержание C043/500

Страница 1: ...USE AND MAINTENANCE MANUAL STAINLESS STEEL ELECTRONIC DIGITAL CALIPER Art C043 500 C043 1000 C047 500 TRANSLATION OF THE ORIGINAL INSTRUCTIONS f e r v i c o m ...

Страница 2: ...documentation cited and or attached It is expressly forbidden to reproduce publish or distribute any information from this Manual Copyright by FERVI Index 1 INSTRUCTIONS 4 1 1 Operation 4 1 1 1 Operation keys 5 1 1 2 Data output 5 1 2 Technical specifications 6 1 3 Applications 6 1 4 Battery replacement 6 f e r v i c o m ...

Страница 3: ...d in this manual Operator Qualification The operators assigned to using this instrument must be supplied with all of the necessary information and instruction and should be provided with adequate training regarding safety in pertaining to a The conditions of use of the equipment b Foreseeable abnormal situations pursuant to Article 73 of Legislative Decree 81 08 We guarantee the Machine s conformi...

Страница 4: ...liper clean the surface of the protective adhesive using a clean dry cloth To remove condensation dirt use a cloth lightly dampened with ethyl alcohol 2 Conditions of use Temperature 5 40 C Relative humidity lower than 80 Prevent the protective adhesive from coming into contact with liquids containing water that can damage the circuit board 3 Do not apply voltage e g impact with an electric pen to...

Страница 5: ...o point by pressing the ABS zero button The measured value corresponds to the movement of the cursor from the relative zero point negative numbers to the left positive numbers to the right SET Pre adjustment button When pressing this button the preset value will be displayed The factory default value is zero Press the SET button and at the same time the or button at the top of the screen the lette...

Страница 6: ...ring the diameter of a hole the value of K has to be inserted If the preset value is zero the measurement plus K is the diameter of the hole If you frequently measure the diameter of holes insert the value K as the preset value See paragraph 3 Operation Keys under the heading SET 4 Relative measurement To check the accuracy of pieces in series measure the sample press the ABS zero button the scree...

Отзывы: