Range Selection
The range is automatically selected by the F-1860. However, should you wish to
select the range manually, this can be done by pressing the RANGE button.
Range Exit
To exit the manual RANGE function and return to automatic mode, keep the
RANGE button pressed for 2 seconds.
NOTE:
♦
If the range is too high, the readings will be less accurate.
♦
If the range is too low, the F-1860 will blink and show OL (Over Limit)
DATA HOLD
The Data Hold feature stores the last reading in the F-1860’s memory.
♦
Press the DATA HOLD button once to hold the present reading.
♦
Press the DATA HOLD button again to exit and resume readings.
Power Reset (PWR RST)
The Power Reset button switches the F-1860 back on when it has automatically
switched itself off.
Power Off Disable
To disable the automatic power off function, keep the PWR RST button pressed
while switching on the F-1860.
Temperature (ºC/ºF)
The temperature can be displayed in degrees Celsius (ºC) or in degrees
Farenheit (ºF).
Press the ºC/ºF button to choose between degrees Celsius (ºC) or degrees
Farenheit (ºF).
CYL Cylinder
Select the DWELL function, then press the cylinder button to choose between
the 4, 5, 6 or 8 cylinder scale.
Trigger
Select the Duty Cycle and Pulse Width function, then press the
±
Trigger button
to choose between the negative (-) or positive (+) slope.