Ferroli TOP FAN Plus rem Скачать руководство пользователя страница 5

5

FOREWORD - REMOTE CONTROL

INFORMAZIONI GENERALI

Il telecomando funziona con due batterie non ricaricabili da 1,5 V.  When the batteries are low, the remote control 

display tends to become dim. If the batteries are not replaced, the display will go off completely.

Fig. 1

Fig. 2

Inserimento batterie:

• Remove the cover of the battery compartment at the back of 

the remote control.

• Remove the used batteries and insert new batteries.

Wait 10 minutes before fitting the new batteries.

The remote control uses two alkaline batteries (1.5 V, LR03x2).

• Do not use used batteries or batteries of different types, as 

this may cause the unit to malfunction.

• The average battery life during normal use is approximately 

one year. The remote control used batteries must be disposed 

of according to the standards in force.

Important:  The  remote  control  will  not  work  for  at  least  10 

minutes between removal of the flat batteries and fitting the 

new ones .

The maximum operating range for the remote control is approx. 

5 m.

No obstructions such as curtains or plants should be between 

control and unit.

Direct sun on the unit receiver may interfere with good signal 

reception ( for VM-B VM-F versions ) ( Fig. 1)  or on the remote 

receiver for VN  units ( Fig. 2)  and press the button for the 

required function.

After selecting the function to be set, press the On/Send button for 

sending the command to the unit.

The operating setting to the unit are sent by the remote control 

through an infrared ray.

The emitter is placed on top of the remote control just over the 

display.

For this reason, the remote control must be directed towards 

the unit before sending any message and care must be taken 

that no obstructions are between the remote control and the 

unit.

The symbol  

 

 on the display left side indicates that the 

message has been correctly sent.

An acoustical acknowledgement sound (beep) will indicate that 

signal has been received.

TIMER

ON

ON/OFF

 

max 800mm

Содержание TOP FAN Plus rem

Страница 1: ...TOP FAN Plus rem Fan coil INSTRUCTION MANUAL EN ...

Страница 2: ...el is kept under constant surveillance FERROLI products therefore offer SAFETY QUALITY and RELIABILITY Due to the continuous improvements in technologies and materials the product specification as well as performan ces are subject to variations without prior notice Thank you once again for your preference FERROLI S p A The manufacturer declines all responsibility for any inaccuracies in this manua...

Страница 3: ...g the fan speed Fan button 8 Current time adjusting Select and buttons 8 Start Stop Select and buttons 9 Timer activation Select and buttons 9 UNIT DISPLAY 10 Unit warning lights 10 Internal unit emergency button 10 Auto restart function 10 ROUTINE MAINTENANCE 11 GENERAL RECOMMENDATIONS FOR CLEANING 11 HOW TO CLEAN THE EXTERIOR PARTS OF THE APPLIANCE 11 HOW TO CLEAN THE AIR FILTER 11 HOW TO DRAIN ...

Страница 4: ...g and must only be used for this purpose The machine can only operate well and be used in a profitable way if used correctly and kept in a fully efficient condition Please read this instruction manual carefully and consult it whenever difficulties arise when the unit is used If required remember that our assistance service which is organized in collaboration with our dealers is always at your disp...

Страница 5: ...inutes between removal of the flat batteries and fitting the new ones The maximum operating range for the remote control is approx 5 m No obstructions such as curtains or plants should be between control and unit Direct sun on the unit receiver may interfere with good signal reception for VM B VM F versions Fig 1 or on the remote receiver for VN units Fig 2 and press the button for the required fu...

Страница 6: ... 2 6 1 4 3 5 B Fig 1 The following functions are settable by means of the remote control Switching the unit 1 On 2 Off 3 Operation mode selection Automatic Heating Cooling Ventilation only requires the presence of valves 4 Fan speed Max Med Min Auto 5 Temperature Set Point 6 TIMER setting C or F The remote control display shows the following settings a Operation mode b Selected fan speed c Set poi...

Страница 7: ...ressing this button the available modes will be selected in sequence The choosen mode is shown as follows while the unit will acknowledge signal receipt with a confirming beep Cool Heat Auto change over Only fan Press On Send to send the information to the thermostat The unit will only emit a beep when the signals are received correctly Temperature setting and buttons Pressing the UP and DOWN butt...

Страница 8: ...eceived correctly Current time adjusting Select and buttons Procedure for setting the current time 1 To set the current time press the Select button 2 The CLOCK SET symbol starts flashing on the display 3 To adjust the hours use the or buttons 4 To confirm the current time press the Select button 5 To adjust the minutes use the or buttons 6 To confirm the current minutes press the Select button Pr...

Страница 9: ...s Procedure for setting switching on time 1 To activate the procedure for setting the switching On Off times press the Select button twice in quick succession 2 The PROGRAM START symbol will start flashing on the display 3 To adjust the hours use the or buttons 4 To confirm the required hour press the Select button 5 To adjust the minutes use the or buttons 6 To confirm the required minutes press ...

Страница 10: ...one timer is activated The YELLOW Led flashes during timer setting in case of power failure and its subsequent reset O Green LED T Yellow LED S Remote control signal receiver Internal unit emergency button It allows turning the unit off and or on in case of a remote control unit fault Operating mode and the preset temperature are automatically adjusted depending on the room temperature at switch o...

Страница 11: ... appliance with care HOW TO CLEAN THE AIR FILTER Proceed in the following way to clean the filter 1 Remove the filter Use a flat screwdriver to do this See fig 1 2 Clean the filter with a vacuum cleaner or wash it with water After washing allow the filter to completely dry away from heat sources 3 Fit the filter back in position and make sure that it has correctly fitted into its housing NOTE It i...

Страница 12: ...er Wrong setting on control panel Check the boiler Change setting on control panel Fails to produce cold No cold water Wrong setting on control panel Check the coolant Change setting on control panel The fan fails to turn No power In winter mode the fan power supply depends on activation of the enabling thermostat if installed The ventilating action will only start when the temperature of the wate...

Страница 13: ... current Refrigerant Kg A V Potenza assorbita Alimentazione Standard Rif norma Input Freddo Cooling Potenza resa Serial N Matricola Code Codice Model Freddo Cooling Rev Modello Kg Hz A B C D E F G H I L M N N O P Q R S T The figure on the left illustrates the identification plate of the unit A Trademark B Model C Code D Serial number E Power delivery during cold mode operation F Power delivery dur...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ...16 Ferroli spa 37047 San Bonifacio Verona Italy Via Ritonda 78 A tel 39 045 6139411 fax 39 045 6100933 www ferroli it COD 3QE ...