CONTROL SYSTEM

Menu

Level

Parameter

Function

Time table 5

Cooling circuit 1

E

600

Preselection

E

601

Phase 1 on

E

602

Phase 1 off

E

603

Phase 2 on

E

604

Phase 2 off

E

605

Phase 3 on

E

606

Phase 3 off

E

616

Default values

Holidays program

Heating circuit 1

E

642

Start

E

643

End

E

648

Operating level

Holidays program

Heating circuit P

E

662

Start

E

663

End

E

668

Operating level

Heating circuit 1

E

710

Comfort set point

E

712

Reduced set point

E

714

Frost Protection set point

E

720

Climatic curve slope

E

730

Summer/winter changeover temperature

Cooling circuit 1

E

901

Operating mode

E

902

Comfort set point

E

907

Release

Heating circuit P

E

1300

Operating mode

E

1310

Comfort set point

E

1312

Reduced set point

E

1314

Frost Protection set point

E

1320

Climatic curve slope

E

1330

Summer/winter changeover temperature

Domestic hot water

E

1610

Nominal set point

E

1612

Reduced set point

Service

Special operations

E

7120

Economy mode

E

7141

Emergency operation

Diagnostic

heat source

E

8410

Heat pump return temperature

E

8411

Set point heat pump return temperature

E

8412

Heat pump flow temperature

E

8427

Source return temperature

E

8429

Source flow temperature

Diagnostic

consumers

E

8700

Outdoor temperature

E

8701

Minimum outdoor temperature

E

8702

Maximum outdoor temperature

E

8740

Room temperature heating circuit 1

E

8741

Set point room temperature heating circuit 1

E

8743

Flow temperature heating circuit 1

E

8744

Set point flow temperature heating circuit 1

E

8756

Flow temperature cooling circuit 1

E

8757

Set point flow temperature cooling circuit 1

E

8800

Room temperature heating circuit P

E

8801

Set point room temperature heating circuit P

E

8803

Set point flow temperature heating circuit P

E

8830

Temperature 1 Domestic Hot Water

E

8831

Set point Domestic Hot Water temperature

E

8980

Temperature 1 Buffer

E

8981

Set point Buffer temperature

E

8982

Temperature 2 Buffer

E

9031

Relay output QX1

E

9032

Relay output QX2

E

9033

Relay output QX3

E

9034

Relay output QX4

E

9035

Relay output QX5

E

9036

Relay output QX6

Содержание HXA

Страница 1: ...HXA AIR WATER HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL i migliori gradi centigradi R E F R I G E R A N T G A S E C O FRIEND L Y 0 55...

Страница 2: ...of experiences and of particular research studies and has been made with top quality materials and advanced technologies The CE mark guarantees that the products satisfy all the applicable European Di...

Страница 3: ...20 Overall dimensions 21 Minimum operating area 21 CONNECTIONS 22 Hydraulic connections 22 Electrical connections 23 RECEIVING AND POSITIONING 24 Receiving 24 Positioning 24 START UP 25 Start up 25 CO...

Страница 4: ...ialized service centers recognized by the manufacturer and use original spare parts The unit must be installed outdoor and connected to a hydronic cooling and or heating system Any use different from...

Страница 5: ...t daily switching programs for heating cooling and domestic hot water production The refrigerant circuit contained in a box repaired from the air flow to simplify the maintenance operations is equippe...

Страница 6: ...adjust itself to the different operating conditions keeping steady the set superheating The refrigerant circuit of each unit contains moreover solid core hermetic filter dryer 5 to restrain impurity a...

Страница 7: ...rmostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control...

Страница 8: ...iciency Integrative electrical heaters Integrate or replace the heating power supplied by the heat pump and are managed by the unit controller with a 3 step logic Soft starter Reduces the compressor s...

Страница 9: ...ess transmitter Connected to the unit controller allows to communicate with wireless remote control and wireless outdoor temperature sensor Wireless repeater Extends wireless operating range Wireless...

Страница 10: ...0 15 0 15 0 15 0 21 0 21 0 42 0 421 kW Plant side hydraulic circuit Expansion vessel volume 10 10 10 10 10 10 10 10 l Plant pump standard option Type 3 speed glandless pump centrifugal pump Quantity...

Страница 11: ...1490 1879 2190 2914 3448 l h Pressure drops plant side 12 17 22 28 41 53 58 52 kPa IP Heating A7W45 source air in 7 C d b 6 C w b plant water in 40 C out 45 C Heating capacity 4 65 5 70 6 76 7 84 9 9...

Страница 12: ...urce air in 7 C d b 6 C w b plant water in 30 C out 35 C Outlet temperature plant side A 55 C B 45 C C 35 C D 25 C Heating capacity Inlet air temperature w b C Inlet air temperature w b C Inlet air te...

Страница 13: ...source air in 35 C d b plant water in 12 C out 7 C Outlet temperature plant side A 24 C B 18 C C 12 C D 7 C Cooling capacity Inlet air temperature w b C Inlet air temperature d b C Inlet air temperat...

Страница 14: ...nsity 1000 kg m3 Flow rate l h Flow rate l h Pressure drops unit without options Pressure drops to be added unit with option Integrative electrical heaters Pressure drops kPa Pressure drops kPa 0 10 2...

Страница 15: ...ant side flow rate management Standard pump Available static head unit with option Plant side flow rate management High head pump Available static head kPa Available static head kPa 0 20 40 60 80 100...

Страница 16: ...e flow rate management High efficiency pump Flow rate l h Available static head kPa The graphs are referred to units operating with water at the temperature of 10 C density 1000 kg m3 0 20 40 60 80 10...

Страница 17: ...mperature d b C Outlet temperature plant side C The graphs reported below show the operating area inside which the correct working of the unit is guaranteed COOLING Inlet air temperature d b C Outlet...

Страница 18: ...1 50 V ph Hz F L A Maximum total current input 0 8 0 8 0 8 0 8 0 8 0 8 1 3 1 3 A F L I Maximum total power input 0 15 0 15 0 15 0 15 0 15 0 15 0 25 0 25 kW Power supply 230 1 50 230 1 50 230 1 50 230...

Страница 19: ...nd power levels dB by octave bands Hz Sound power level Sound pressure level at 1 metre at 5 metres at 10 metres 63 125 250 500 1000 2000 4000 8000 dB dB A dB A dB A dB A 5 1 73 6 71 5 69 8 66 1 62 6...

Страница 20: ...nt side flow rate management Standard pump 7 7 7 7 7 7 14 14 kg High head pump 9 9 9 9 14 14 15 15 kg High efficiency pump 7 7 7 7 8 8 8 8 kg Integrative electrical heaters 5 5 5 5 5 5 5 5 kg Unit wit...

Страница 21: ...revalenza 1 1 M 1 M 1 M 2 1 M 1 M 1 M 3 1 M 1 M 1 M 4 1 M 1 M 1 M D 509 mm 759 mm 1059 mm E 535 mm 646 mm 946 mm F 177 mm 427 mm 727 mm G 569 mm 819 mm 1119 mm L 155 mm 155 mm 97 mm 97 mm H 903 mm 115...

Страница 22: ...o the fitting supplied as standard with all the units Expansion vessel setting The precharge pressure of the expansion vessel must be adequate to the total volume of the hydraulic circuit at which the...

Страница 23: ...ferring to the total FLI and FLA values of the unit taking into account the selected options except the integrative electrical heaters and the installed accessories Integrative electrical heaters powe...

Страница 24: ...o avoid damages to the unit Prevent the unit or parts of it from falling down Storing The units must be stored in a dry place repaired from sun rain sand or wind Do not stack the units Maximum tempera...

Страница 25: ...e caused some loosening 3 Connect the unit power supply line and verify that the voltage of the power supply line complies with the the nominal one of the unit for three phase power supply units the u...

Страница 26: ...daptor for outdoor temperature sensor G wireless remote control H and wireless repeater I to be used to amplify the signal when the distance between the devices is large The remote control can be used...

Страница 27: ...Cooling circuit 1 mixed Zone 2 Heating HCP Heating circuit P NOT mixed Zone 1 HC1 CC1 HCP Zone 2 Remote control 40 Room unit 1 42 HC1 Remote thermostat ru 3 HCP Zone 1 HC1 CC1 HCP Zone 2 Remote therm...

Страница 28: ...1 5 meters above the floor in the case of wall mounting enough clearance above the device must remain enabling it to be fitted and removed The power supply of the remote thermostat and of the remote...

Страница 29: ...ted to the adaptor through a two wire cable the wires are interchangeable WIRELESS TRANSMITTER The transmitter must be connected to the X60 terminal of the heat pump controller Before connecting the t...

Страница 30: ...elect the opera ting level COMMISSIONING and press OK Select the menu WIRELESS and press OK Set the parameter 121 TEST MODE as ON and press OK The digits on the left show the telegrams sent the digits...

Страница 31: ...th a temperatu re sensor to measure the room temperature of the zone that it manages Also the remote thermostat contains a temperature sensor to measure the room temperature but allows the access to a...

Страница 32: ...ing mode Frost Protection room temperature controlled according to Frost Protection set point protective functions active ECO functions active automatic summer winter changeover and automatic 24 hour...

Страница 33: ...formations about the operating status of the system can be displayed The list of informations changes according to the type of unit the plant configuration and the active operating mode When error or...

Страница 34: ...FO button for at least 3 seconds select the user name with the knob and press the OK button select the desired menu and press OK To modify the parameters inside the menus select the desired parameter...

Страница 35: ...E 7120 Economy mode E 7141 Emergency operation Diagnostic heat source E 8410 Heat pump return temperature E 8411 Set point heat pump return temperature E 8412 Heat pump flow temperature E 8427 Source...

Страница 36: ...uit always activated 24 hour per day activate the circuit according to time table 5 activate the circuit according to heating circuit 1 time table For each time table it is possible to specify the pro...

Страница 37: ...or temperature is lower than a fixed limit parameter 3700 in order to realize a bivalent operation Heating circuits climatic curves setting The climatic curves allow to calculate the flow temperature...

Страница 38: ...hanger outlet temperature temperature sensor NTC 10K BX4 B71 plant heat exchanger inlet temperature temperature sensor NTC 10K BX5 temperature sensor NTC 10K x H1 Heating request voltage free digital...

Страница 39: ...e scheduled delays at the unit switch on are ignored avoiding undesired waiting times during commissio ning or fault tracing This function should NOT be used in normal operation Alarm history The cont...

Страница 40: ...esolution 0 1 C Tolerance 1 0 C Power supply 3 alkaline batteries 1 5 V type AA LR06 Communication wireless BSB bus frequency 868 MHz Safety class EN 60730 III Degree of protection EN 60529 IP 20 Oper...

Страница 41: ...sensor is at the temperature of 25 C the electrical resi stance measured at the sensor ends is 1 kW for the NTC 1K sensor and 10 k for the NTC 10K sensors The thermistor of these sensors has a negativ...

Страница 42: ...ly cable that connects the unit to the distribution panel is not affected by cuts cracks or alterations that could compromise the insulation Contact an authorized service center if maintenance is requ...

Страница 43: ...ON OF HAZARDS Identification of hazards Liquefied gas The vapours are heavier than air and can cause suffocation reducing the oxygen available for brea thing Rapid evaporation of the fluid can cause f...

Страница 44: ...ort Avoid transport on vehicles where the loading zone is not separate from the cab Make sure the driver is informed about the potential risk of the load and knows what to do in case of accident or em...

Страница 45: ...45...

Страница 46: ...manufacturer declines all responsibility for any inaccuracies in this manual due to printing or typing errors The reserves the right to modify the products contents in this catalogue without previous...

Страница 47: ...47...

Страница 48: ...Ferroli spa 37047 San Bonifacio Verona Italy Via Ritonda 78 A tel 39 045 6139411 fax 39 045 6100933 www ferroli it COD 3QE26614...

Отзывы: