FALCON II
38
JP01 ON
= Delay between shutdown and re-ignition disabled
JP01 OFF
= Delay between shutdown and re-ignition enabled
JP02:
Jumper on for natural gas
Jumper on for LPG
JP03 ON
= Max temperature D.H.W. 62°C
JP03 OFF
= Max temperature D.H.W. 55°C (standard)
Potentiometer adjustment
P1
= Central heating flow temperature adjustment
P2
= Domestic hot water temperature adjustment
P3
= Central heating flow output adjustment
P4
= Ignition gas pressure adjustment
P5
= Minimum adjustment pressure
9. ELECTRICAL AND FUNCTIONAL SCHEME
9.01 Main components layout on electronic boards
temp. Ohm
10 °C 20 kOhm
25 °C 10 kOhm
60 °C 2,5 kOhm
80 °C 1,25 kOhm
Temp.
sensor
NTC
(34) (42)
Fig. 34
X6
X1
X2
X3
X4
1
2
1
2
1
3
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
11
12
13
2
1
X5
L1
L2
L3
L4
L5
+
-
+
-
Transformer
P2
DHW
X12
1
2
+
-
P3
+
-
P5
+
-
P4
JP02
JP01
JP03
1
2
3
4
5
6
7
8
9
X10
Nat/LPG
P1
CH
X11
RY100
RY101
PC
PNO
L
N
HL
HL
MV1 MV2 MV3 MV4
FAN
L
N
X8
X7
MF03F