A
Attention
: Before connecting the
collector temperature sensor
, remove the resistance between terminals 5
and 6 of controller
DBM29
.
A
Attention
: Before connecting the
room thermostat
on the direct zone, remove the jumper on the terminal
block .
A
Attention
: The boiler is arranged for operation with
room thermostat
on the low temperature zone. On con-
necting the
remote timer control
it will be necessary to configure the controller
FZ4B
. To do this, press the
AUTOCFG
button (see fig. 37) until all the LEDs of the
FZ4B
card flash. The boiler will then be ready to operate
with remote timer control on the low temperature.
To reconnect the room
thermostat
in place of the
remote timer control
, carry out the above procedure again,
bringing the room thermostat to demand status (voltage-free contact).
fig. 37 - Controller FZ4B
AUTOCFG
OK
-
+
FZ4B