2.6 Flues
The unit is “C type” with sealed chamber and forced draught, the air inlet and fume outlet must be connected to one of
the following extraction/suction systems. The unit is approved for operation with all the Cxy flue configurations specified
on the dataplate (some configurations are given by way of example in this chapter). Some configurations, however, may
be expressly limited or not permitted by laws, standards or local regulations. Before carrying out installation, check and
carefully respect the relevant prescriptions. Also, comply with the provisions on wall and/or roof positioning of terminals
and the minimum distances from windows, walls, vents, etc.
B
This C-type unit must be installed using the fume extraction and exhaust pipes supplied by the manufacturer
in compliance with UNI-CIG 7129/92. Failure to use them automatically invalidates any warranty and relieves
the manufacturer of all liability.
A
In the installation phase, for flues longer than 1 m, the natural expansion of the materials during operation must
be taken into consideration.
To prevent deformations, leave an expansion space of approx. 2 - 4 mm for every metre of pipe.
fig. 9 - Expansion
2 ÷ 4 mm