2.2 Hydraulic circuit – tap water
Hydraulic diagram for tap water
20
82
5
29-187
16
- +
44
7
81
43
32
14
114
34
11
10
49
50
222
36
97
155
130
179
179
74
8
9
192
151
56
The tap water is supplied via an integrated boiler. It is heated indirectly by a coil in the boiler. The primary water
circulates in the coil thanks to a pump and is kept at a temperature of 85°C by the heating sensor. When the
temperature detected by the boiler sensor is 1°C lower than the set temperature, the heating pump stops and
the tap-water pump starts up immediately. In this way, heating is turned off and the boiler exchanges with the
closed circuit water that in its turn yields the heat to the tap water contained in the boiler.
Key
5
Airtight chamber
7
Gas inlet
8
Tap water outlet
9
Tap water inlet
10
System delivery
11
System return
14
Safety valve
16
Fan
20
Burner assembly
29
Fume outlet manifold
32
Heating circulator
34
Heating temperature sensor
36
Automatic air vent
43
Air pressure switch
44
Gas valve
49
Safety thermostat
50
Heating thermostat
56
Expansion tank
74
Heating system cock
81
Ignition electrode
82
Detection electrode
97
Magnesium anode
114
Water pressure switch
130
Boiler circulator
151
Boiler drain cock
155
Boiler temperature sensor
179
Check valve
187
Fume diaphragm
192
Recirculation
222
Copper exchanger