![Ferroli DIAMANT S Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/ferroli/diamant-s-series/diamant-s-series_use-and-maintenance-manual_2282178022.webp)
EN
Cod. 3QE46130 - Rev. 00 - 11/2019
DIAMANT S
22
1.5 TECHNICAL DATA
MODEL
9
12
18
24
U.M
Power Supply
230-1-50
V-f-Hz
Cooling Capacity (1)
Rated
2640
3520
5280
7040
W
Min-Max
910-3400
1115-4160
1820-6130
2080-7950
W
Power Input at Cooling (1)
Rated
710
1237
1539
2345
W
Min-Max
100-1240
130-1580
140-2360
160-2690
W
Rated current at Cooling (1)
3,1
5,4
6,9
10,2
A
Moisture removal (1)
0,8
1,4
1,8
2,4
l/h
EER ref. Standard EN14511 (rated) (1)
Rated
3,72
2,85
3,43
3,00
W/W
SEER ref. Standard EN14825
6,20
6,10
7,10
6,10
W/W
PdesignC
2,6
3,5
5,2
7,0
kW
Heating Capacity (2)
Rated
2930
3810
5570
7330
W
Min-Max
820-3370
1085-4220
1380-6745
1610-8800
W
Power Input at Heating (2)
Rated
739
964
1480
2035
W
Min-Max
120-1200
100-1580
200-2410
260-3140
W
Rated current at Heating (2)
3,3
4,2
6,6
9,2
A
COP ref. Standard EN14511 (rated) (2)
Rated
3,96
3,95
3,76
3,60
W/W
SCOP ref. Standard EN14825
4,00
4,00
4,00
4,00
W/W
Climate Zone ref. Standard EN14825
A (tempered)
Tipo
PdesignH
2,1
2,3
4,1
4,8
kW
Temp balance Tbiv
-7
-7
-7
-7
°C
Temp use limit Tol
-15
-15
-15
-15
°C
Efficiency class Standard 626/2011 Directive
2009/125/CE
Cooling
A++
A++
A++
A++
\
Heating
A+
A+
A+
A+
\
Stand-by mode power consumption
0,5
0,5
0,5
0,5
W
Air flow (Max-med-min)
520/460/360 600/500/360 840/680/540
980/817/662
m3/h
Sound pressure level (Max-med-min) (3)
40/30/26/21
40/34/26/22
43/37/30/25 44,5/42/34,5/28 dB(A)
Sound power level (max)
53
53
55
59
dB(A)
Outdoor unit air flow
1700
1700
2500
3000
m³/h
Sound pressure level outdoor unit (3)
55,5
56
56
59,5
dB(A)
Sound power level outdoor unit
61
65
61
67
dB(A)
Refrigerant
R32
Tipo
GWP
675
tCO2 eq.
Charge
0,5
0,5
1,0
1,6
Kg
Liquid connection
1/4
1/4
1/4
3/8
inch
Gas connection
3/8
3/8
1/2
5/8
inch
Max refrigerant pipe lenght
25
25
30
50
m
Max height difference
10
10
20
25
m
Net weight indoor unit
7,5
7,5
10
12,3
Kg
Net weight outdoor unit
22,7
22,7
34
51,5
Kg
Packing dimension indoor unit
W
870
870
1035
1120
mm
H
270
270
295
310
mm
D
360
360
380
405
mm
Packing dimension outdoor unit
W
815
815
920
965
mm
H
615
615
615
765
mm
D
325
325
390
395
mm
Note:
(1) External air temperature = 35°CDB • Ambient air temperature = 27°CDB / 19°CWB
(2) External air temperature = 7°CDB / 6°CWB • Ambient air temperature = 20°CDB
(3) Sound pressure level detected at a distance of 1 m: External unit in free-field condition, Internal unit in a 100m3 environment with reverberation time
of 0.5 seconds.