BLUEHELIX TECH RRT 24 H
189
EN
cod. 3541C661 - Rev. 00 - 10/2018
Removing the diverter valve
A
Before carrying out the following instructions it is advisable to protect the room and the boiler’s electrical box
against accidental water spillage.
fig. 45
•
Disconnect the power supply and turn off the gas cock ahead of the valve.
•
Remove the diverter valve connector.
•
Remove the clip
“1”
and remove the diverter valve
“2”
.
Replacing the water pressure switch
A
Before carrying out the following instructions it is advisable to protect the room and the boiler’s electrical box
against accidental water spillage.
fig. 46
•
Disconnect the power supply and turn off the gas cock ahead of the valve.
•
Remove the connector
“1”
and fastening clip
“2”
.
•
Remove the water pressure switch
“3”
.
1
2
1
2
3