ARENA 30 A
38
Display and boiler off
• Power failure
• Check or await the return of the
electrical power supply
Radiators cold in winter
• Room thermostat
adjusted too low or
defective
• Adjust the knob to a higher
temperature, replace if
necessary
Radiators hot in summer
• Room thermostat
adjusted too high or
defective
• Adjust the knob to a lower
temperature, replace if
necessary
Large variations in
domestic hot water
temperature
• Water flow rate too low
• Increase the water flow rate
(minimum three litres per minute)
Fault
Possible cause
Solution
Low domestic hot water
flow
• Insufficient mains water
pressure
• Heat exchanger with
passages partially blocked
• Install a pressure increase
device
• Request the cleaning of the
heat exchanger
No domestic hot water
flow
• Heat exchanger
blocked
• Defective flow-meter
• Request Engineer for the cleaning
operations
• Request Engineer for the
replacement of the flow-meter
No temperature increase
with boiler on
• Boiler dirty
• Boiler insufficient
• Check and clean the boiler body
• Check that the boiler is the right
capacity for the requirements of
the heating system
Loss of condensation from
the boiler
• Condensation discharge
blocked
• Check and clean the drain
trap