ARENA 30 A
26
7
Unscrew the fastening screws “C” and remove the Venturi unit + gas valve
8
Unscrew the three fastening screws “D” and separate the gas valve and the Venturi
9
Replace the diaphragm “E”, making sure the new restrictor and the gasket are repositioned correctly
inside the housing in the valve body
10
Reassemble the gas valve, ignition device, connections, following the previous instructions in the
reverse order
11
Check the seal of the gas connections
12
Insert the probe of a combustion analyzer in the outlet flue gas of the boiler
13
Turn on the boiler and bring the burner to the maximum power: it is advised to open one or more
DHW taps and verify on the display that the parameter 8 (boiler power) arrives to 99.
14
By means of the analyzer, note the CO
2
content in the flue gas with boiler to maximum power
15
If necessary, slowly operate on the regulation screw F (fig.19) placed on the Venturi to bring the CO
2
content to the nominal value (/- 0.1%) expected in the table for the correspondent gas type.
It is recommended to operate only on the screw F and not on the gas valve: this operation could
compromise the correct functioning of the appliance
16
Once the regulation has been made, apply the orange plate contained in the transformation kit next
to the data plate and reassemble the boiler casing and the lower protection plate.
Fig. 20
E
Содержание ARENA 30 A
Страница 32: ...ARENA 30 A 32 fig 23g fig 23f fig 23h N O ...