![Ferroli AquaSol Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/ferroli/aquasol/aquasol_installation-and-user-manual_2281847008.webp)
M 1261-06-X AquaSol Ferroli Installation Manual.doc
July 2006
Page 8 of 24
7.1
Before connecting this unit:
•
For the installation of a complete Solar system planning permission may be
required especially if the building is located in a conservation area or is a
listed building. These solar thermal systems are classed as a 'permitted
development'. It is however advised to check with the local planning
department prior to installation.
•
Ensure that incoming mains pressure is adequate: minimum 1.5 Bar, but
less than 10 Bar. This information may be obtained from the local water
authority, or by conducting a mains pressure & flow test.
•
Excessive use of flux can damage this unit, especially the check valves.
Avoid over-use, and ensure that the system and all pipe work is flushed to
BS7593, thus removing all contaminants prior connecting to the AquaSol.
•
Ensure that the discharge pipe (tundish) and drain valve are positioned
away from any electrical components.
7.2
Assembling the Pump and filling manifold
Figure 1
Assemble the pump and filling manifold as shown in Figure 1. Do not attach the
expansion relief module at this time, as it is required to be detached for the system
filling process.
Correct pump orientation