FORCE B
133
EN
cod. 3541T170 - Rev. 00 - 09/2019
Adjustments from remote timer control
A
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accor-
ding to that given in table 1.
Table 1
System water pressure adjustment
The filling pressure with the system cold must be approx. 1.0 bar. If the system pressure falls to values below minimum,
the boiler card will activate
fault 37 and the number of the module
(fig. 30).
fig. 30 - Module 1 insufficient system pressure fault
A
Once the system pressure is restored, the boiler will activate the 300-second air venting cycle indicated on the
display by FH.
Heating temperature adjustment
The adjustment can be made from the Remote Timer Control menu and the boiler control panel.
DHW temperature adjustment (with
optional hot water tank installed)
The adjustment can be made from the Remote Timer Control menu and the boiler control panel.
Summer/Winter Switchover
Summer mode has priority over a possible Remote Timer Control heating demand.
Eco/Comfort selection
(with optional hot
water tank installed)
On disabling DHW from the Remote Timer Control menu, the boiler will select the Economy
mode. In this condition, the button detail 10 - fig. 1 on the boiler panel is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler will select the Comfort
mode. In this condition, with the button detail 10 - fig. 1 on the boiler panel it is possible to select
one of two modes.
Sliding Temperature
Both the Remote Timer Control and the boiler card manage Sliding Temperature adjustment:
Sliding Temperature overrides the boiler card.
Nr:37
Src:1