Digital Interfaces
device's output will be connected to the next device's input.
Hence you can connect, for example, four A16 AE in a row in
order to use the maximum number of 64 MADI channels.
For more information concerning the MADI upgrade please
visit our website: www.ferrofish.de/upgrade
WORDCLOCK
When using many devices which should run with the same
sample rate, it is a good idea to use the Wordclock (BNC)
connection of the A16 AE. It has both in and out connections
to synchronize timings between multiple devices. The A16 AE
can output a master wordclock, or accept (and then throughput)
a signal from other devices.
status screen
The
status screen
is a useful help when configuring the
A16 AE, giving an overview of the digital inputs. To activate
it, press
MENU
and then select
status
. The screen shows for
every digital input, whether it receives a valid signal (
signal
)
and whether this signal's sampling rate is correct (
lock
). Only if
both conditions are met, the A16 AE will use the signal.