BLUEHELIX MAXIMA
220
EN
cod. 3541U630 - Rev. 03 - 11/2020
Periodical check
To ensure proper operation of the unit over time, have qualified personnel carry out a yearly ins-
pection, providing for the following checks:
• The control and safety devices (gas valve, flow meter, sensors, etc.) must function correctly.
• The fume exhaust circuit must be perfectly efficient.
• The sealed chamber must be tight.
• The air-fume end piece and ducts must be free of obstructions and leaks
• The burner and exchanger must be clean and free of deposits. Use suitable brushes for clea-
ning. Never use chemical products.
• The electrode must be properly positioned and free of any deposits.
The electrode can be cleaned of incrustations only with a non-metallic brush, and must NOT
be sanded.
• The gas and water systems must be tight.
• The water pressure in the system when cold must be approx. 1 bar; otherwise bring it to that
value.
• The circulating pump must not be blocked.
• The expansion vessel must be filled.
• The gas flow and pressure must match that given in the respective tables.
• The condensate evacuation system must be efficient with no leakage or obstructions.
• The trap must be full of water.
• Check the quality of the water in the system.
• Check the condition of the insulation of the exchanger.
• Check the gas connection between the valve and Venturi.
• Replace the burner gasket if damaged.
• After the check, always control the combustion parameters (see "checking the combustion va-
lues").
Cleaning the exterior surfaces
So as not to alter the opacity of the
painted
plastic panel
(ref. A fig. fig. 32) use mild de-
greasers that do not contain Mek or aggres-
sive alcohols.
To clean the
glass panel
(ref. B fig. fig. 32),
use isopropyl alcohol.
To clean the
side panels
(ref. C fig. fig. 32),
use a mild detergent.
fig. 32