cod. 3541U630 - Rev. 03 - 11/2020
System diagnostics
The values of the sensors and actuators in the boiler are available.
Note:
To return to the
Service Menu
, touch the arrow at the top left of the screen
Transparent Parameters “B” menu
A
By selecting a parameter on the screen, the possible values will be shown. If the values
shown do not match those indicated in the corresponding "Range" column, check that the
parameter
B01
is correctly set to
RRT
.
Description
Range
Combustion
Burner power
00%=Min., 100%=Max.
Flame status
00÷255
Fan rpm
00÷120
Operating hours
00÷99
Fume Temperature
0÷125 °C
Hydraulics
Heating Flow
0÷125 °C
Heating Return
0÷125 °C
NTC DHW sensor (°C)
0÷125 °C
DHW draw-off
00÷99 L/min
Modulating pump speed
00÷100%
System water pressure
00-9.9 bar with pressure transducer
Environment
External probe
+70 ÷ -30°C
Code Description
Range
Default
B01
Boiler type selection
RRP
(INSTANTANEOUS COMBI)
RRH
(HEATING ONLY also with OPTIONAL HOT WATER STO-
RAGE TANK
RRT
(COMBI HEATING ONLY)
RRK
(HEATING ONLY with HOT WATER STORAGE TANK)
RRT
B02
Exchanger type
1 ÷ 4
BLUEHELIX MAXIMA 24C
= 1
BLUEHELIX MAXIMA 28C
= 2
BLUEHELIX MAXIMA 34C
= 3
B03
Absolute Maximum Heating
Power
0 ÷ 100%
(Do not modify the value)
BLUEHELIX MAXIMA 24C
= 75%
BLUEHELIX MAXIMA 28C
= 85%
BLUEHELIX MAXIMA 34C
= 85%
B04
System water pressure pro-
tection selection
Pressure switch
Pressure Transducer
Pressure transducer
B05
NOT IMPLEMENTED
--
B06
Variable input contact ope-
ration selection
Flow meter exclusion
System thermostat
Second room therm.
Warning/Alert
Safety thermostat
Second room thermostat
B07
Relay card LC32 selection
External gas valve
Alarm
System filling solenoid valve
Solar 3-way valve
Second heating pump
Alarm2
Burner lit
Frost protection active
System filling solenoid valve
B08
Hours without DHW draw-
off
0 ÷ 24 hours (time for temporary deactivation of comfort mode
without draw-off)
24