Safe Decontamination of Equipment 

 

It is also suggested to disinfect your Trolley at regular intervals to maximise infection 

control. Where body fluids or blood are suspected of being present, wash down the 

unit after use, using a germicidal detergent adequate for inactivating HIV and 

the HBV virus. 

 

Adequate protective clothing must be worn, to protect yourself and others from 

hazards present in a typical workshop environment. 

 

• Safety Glasses/Goggles or Full-Face Protector 

• Dust/Vapour Protector Mask 

• Rubber/Leather Gloves 

• Clinical Waste Disposal Container 

 

It is recommended that disinfectant that is not chlorine, phenolic or iodine-based is 

used to disinfect equipment as these chemicals can cause surface damage with 

regular use and contact, especially on certain materials and metal finishes such as 

anodizing, zinc plating etc.      

 

If these type of disinfectants are to be used, then to minimise the level of damage 

they will cause it is recommended that they are used with the least possible contact 

time, diluted as specified by the manufacturer’s guidelines, and that the equipment is 

then thoroughly washed down with water after disinfecting in order to remove any 

chemical residue and prevent any ongoing surface damage from occurring. 

 

Any attachable accessories should be cleaned/disinfected whilst detached from the 

trolley. For example, trolley push poles should be removed from the corner sockets 

before both the trolley and poles are cleaned and disinfected, and everything then 

thoroughly washed down with water. 

 

Following these guidelines will ensure effective disinfecting whilst minimising any 

long-term damage and keeping equipment in good operable condition. 

 

Trolley maintenance lubrication

 

 

Your Ferno CCT trolley will work efficiently and safely only when it is well lubricated. 

You MUST lubricate all moving  and sliding parts after every inspection or 

preventative maintenance programme, or  if there is inadequate lubrication for the 

moving parts to operate easily and quietly. 

 

In general terms, almost all sliding and moving parts may be lubricated with a light 

duty grease. A penetrating fluid  lubrication is  used on some sliding parts  of the 

trolley.  However, when a penetrating fluid lubricant is used, all excess MUST be 

wiped away, to prevent any build-up of dust or grime, which can clog up working 

parts and impede movement. 

 

 
 

Содержание CCT Six-P

Страница 1: ...CT Six P User Manual IMPORTANT NOTE To comply with EN 1789 the patient body harness and leg straps MUST be used at all times to hold the patient on the trolley and the trolley MUST be secured in the v...

Страница 2: ...Six P s fixed height is higher than that of the Falcon transport height Furthermore the stability of the trolley within the locking device could be affected by the addition of care equipment this equi...

Страница 3: ...Patient platform total max SWL including 181 kg PacRac 10kg equipment max 25kg if fitted In addition 80kg of medical equipment can be mounted equally spaced on the trolley base If foot end Fixed plat...

Страница 4: ...s for damage if any damage is found it must be replaced 2 Do the trolley sides raise and lower properly 3 Check that the wheels and brakes operate satisfactorily 4 Study this manual before use Practic...

Страница 5: ...trolley by firmly grasping the main frame for added control Trapping hazards cannot be eliminated due to the operation of this product EXTRA CARE to be taken whilst raising and lowering the back rest...

Страница 6: ...Close the restraints around the patient see page 9 6 Raise the cot side rails 7 Make adjustments as necessary Wheeling the Trolley 1 Transporting a patient should be done with the side rails raised an...

Страница 7: ...e vehicle Manual Foot End Lock 5 Ensure that the pedal on the foot end lock is depressed and guide the trolley into the head end floor lock The foot end will automatically lock when the trolley is in...

Страница 8: ...sed and guide the trolley into the head end floor lock The foot end will automatically lock when the trolley is in the correct position Unloading the trolley from a vehicle fitted with a tail lift 1 M...

Страница 9: ...nd must remain fitted to the floor of the vehicle 2 Installation of Head End Lock Assembly As shown in diagram A left ensure handle and blade of locking devices are in the fully open up position Adjac...

Страница 10: ...ing clear 2 Installation of Head End Lock Assembly On each Unwin locking device rotate the plunger crossbar until it snaps into the U slot on the turret diagram A below Do not rotate the turret clockw...

Страница 11: ...ent onto the trolley using recognised techniques 5 Buckle the harness by inserting all three tangs into the buckle until they lock in place or pass the tang through the shoulder straps and secure in t...

Страница 12: ...ort for CPR DO NOT use the backrest to manoeuvre the stretcher under any circumstances When using the stretcher as a seat in a PTS vehicle ensure the headrest is in its lowest position Headrest The CC...

Страница 13: ...til fingers contact the support bar on the underside of the leg rest frame At this point simultaneously lift and move the support bar forward thus releasing same from its locked position and slowly lo...

Страница 14: ...rvice records A sample maintenance record sheet is provided at the end of this manual which can be used to log each maintenance service When documented service can be shown to have been followed and a...

Страница 15: ...ly 2 Repeatedly dip the webbing in clear water to rinse Do not immerse any metal buckles or fixation clips 3 Hang the restraints to air dry Attach only clean dry restraints back onto to the equipment...

Страница 16: ...elines and that the equipment is then thoroughly washed down with water after disinfecting in order to remove any chemical residue and prevent any ongoing surface damage from occurring Any attachable...

Страница 17: ...brake operate properly rotate fully and have adequate tread Does the trolley move smoothly Are the restraints mattress and harness in good condition with no cuts or frayed edges If not then they must...

Страница 18: ......

Страница 19: ...Ferno Trolley Service Log Trolley Model Serial Number Date placed into operation Date of Service No of lifts Remedial work carried out Comments Name...

Страница 20: ...FERNO MAN 0719 162 R07 UK Page 22...

Страница 21: ...l discounts can be offered if a 5 year contract is taken out with a guarantee to hold the price for the effective contract period Pay annually or as the service is completed helping you to control you...

Страница 22: ...General Safety and Performance Requirements within Annex 1 of EC Regulation 2017 745 Registered Office Ferno UK Limited Ferno House Stubs Beck Lane Cleckheaton West Yorkshire England BD19 4TZ Tel 44 0...

Отзывы: