Parameter Value
Meaning
Basic
48 c
keyboard connection
0
c
–
c=0
only NC-mode connected to the basic module
c=1
the keyboard connected on the first position
c=2
the keyboard connected on the second position
c=3
the keyboard connected on the third position
ATTENTION !!
This parameter setting will sharply influence whole guard
function.
List of related parameters:
1 2 32 33 34 47 49 53 8# 84
Parameter Value
Meaning
Basic
49 o
keyboard mode
0
o
–
o=0
dialing as on normal telephone (all number of called person should
be pressed on keyboard).
o=1
Only 2-digit memory number is entered on keyboard by which the
number of called person is stored (memory number corresponds to button
number with respect to Day/Night switchover).
ATTENTION !!
This parameter setting will sharply influence keyboard function.
List of related parameters:
1 2 47 48 53 8# 84
This parameter is avalaible only in version firmware 7.8
Parameter Value
Meaning
Basic
40 d
dialing DTMF from keyboard during talk
0
d
–
d=0
dialing DTMF from keyboard during talk is disabled
d=1
dialing DTMF from keyboard during talk is enabled and key=*
d=2
dialing DTMF from keyboard during talk is enabled and key=#
d=3
dialing DTMF from keyboard during talk is enabled and key=A
4.4 Time Parameters
Parameter Value
Meaning
Basic
51 q
number of rings before guard call lifting up
2
q
– Number of incoming call rings, the guard lifts up among rings namely 2
sec. after detection
q
– times rings. The number can be set from 1 to 9.
List of related parameters:
44 8# 85