![Fermax DUOX Programmer Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/fermax/duox-programmer/duox-programmer_installer-manual_554261048.webp)
This function allows for the measurement of a specific point (where we place the
programmer), of the level of frames sent by the different devices within the installation.
This way we can analyse problems within the installation, due to attenuations in the signal
due to the distance, cable section, power supply, etc., without having to compare the
programmer's measurements in different points of the installation.
Three types of data are offered.
FRAME MEASUREMENT MODE (M.I.)
We start in option 3. METER from the MAIN MENU
Exit this selection and return to the MAIN MENU
Measuring the
DATA FRAME
Measuring UPLOAD AUDIO
FRAMES from channel 1
In any of the three measurements, the information presented may be incomplete due to
the fact that at the moment of measurement not all of the information is available for one
of the following reasons:
None of the selected types of frames have been produced yet.
The information will automatically appear the moment it is generated.
The frames are being monitored (there is audio in the selected direction),
but the device it is coming from could not be identified.
The information will be completed the moment in which a device begins
sending said frame, since this is the moment when the device is identified.
For this, follow these steps indicated in the diagram:
DC Voltage in the bus
Average voltage of the
positive peaks in the data
frame
Address of the device
where the branch
originates
Measuring DOWNLOAD AUDIO
FRAMES from channel 1
POWER: 18.52V
0000000: 03.14V
POWER: 18.52V
0000000: 03.14V
POWER: 18.52V
0000000: 03.14V
3. METER
3. METER
ALL
3. METER
AUDIO UPLINK
3. METER
AUDIO DOWN LINK
OK
OK
OK
OK
POWER: 18.52V
0000000: 03.14V
POWER: 18.52V
0000000: 03.14V
POWER: 18.52V
0000000: 03.14V
ESC
POWER: 18.52V
SIGNAL: - -.- -V
POWER: 18.52V
SIGNAL: 03.14 V