![Fermax 100 CODE MEMOKEY cityline Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/fermax/100-code-memokey-cityline/100-code-memokey-cityline_userand-installers-manual_554227025.webp)
Pag 25
Memokey
Memokey
3
Select the option
you
require:
0:
The all purpose output is not used (by
default). The auxiliary output remains de-
activated.
1:
Each time a valid code is entered a 1
second pulse will be generated.
2:
Every time Relay 1 is activated the all-
purpose device will also activate, and will
remain activated for 5 seconds longer than
the associated device.
3:
The all purpose output will switch every
time a valid code is entered.
4:
The all purpose output will be activated
and will remain active every time you press
“A” and a valid keypad code, (purpose
output will remain during 1 minute active).
5:
The all purpose output activates once 5
erroneous codes are entered in order, and
will remain active for 5 minutes or until a
valid code is entered.
6:
The all purpose output activates once
any key is pressed or deactivates after 15
seconds with inactivity.
Bip
(3 x)
Example: Enable auxi-
liary output.
1480 A8 1