![Fermax 100 CODE MEMOKEY cityline Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/fermax/100-code-memokey-cityline/100-code-memokey-cityline_userand-installers-manual_554227023.webp)
Pag 23
Memokey
Memokey
NOTE:
The most common case is that of normally deactivated
devices such as normal lock-releases for example. The
inversely operated lock-releases on the other hand are
normally activated devices.
1
Enter programming
mode:
Code Master
(1480)
Bip
(3 x)
2
Enter the relevant option:
A2
Relay 1 (lock-release)
A3:
Relay 2 (additional
electrical device activa-
tion)
A2 or A3
Bip
(3 x)
3
Enter the new activation
code or select bistable
mode:
00:
Bistable Mode
01..99:
(01 to 99 se-
conds
Bip
(3 x)
4
Enter
1
if the device is
normally deactivated.
Enter
0
if the device is
normally activated.
1 or 0
Bip
(3 x)
Example: Change the re-
lay timing to 5 seconds and
normally deactivated.
1480 A2 05 0