The gas pressures at the burner and gas flows during the
central heating phase
given in the table refer to
nominal
boiler output
. To reduce this output (where necessary), gas pressure must be reduced until the required output level is
reached (see figures 4 and 5).
During domestic hot water production
, gas pressures to the burner
must correspond to the maximum output given in table
for the type of gas
.
Gas pressure must be adjusted during maximum draw-off of domestic hot water.
• Maximum working temperature for central heating flow: 85
°
C
• Maximum temperature of domestic hot water: 55
°
C, adjustable between 40
°
C and 55
°
C.
• Minimum domestic cold water pressure required for 95% heat input:
- Flow restrictor fitted (standard) - 1,2 bar;
- Flow restrictor removed - 0,5 bar
Technical Data
MODEL
Heat output
Heat
input
Domestic hot
water heat
input
Boiler water
contents
Domestic hot
water circuit
contents
kW
kW
kW
kW
kW
Litres
Litres
FALCON
23,3
9,7
25,8
11,5
23,3
1,5
0,8
MODEL
Connections
Expansion vessel
Max. working
pressure
central heating
circuit
Max. working
pressure hot
water circuit
1
2
3
4
5
Capacity
Pre-pressurising
value
Ø
Ø
Ø
Ø
Ø
Litres
bar
bar
bar
FALCON
3/4"
1/2"
1/2"
1/2"
3/4"
7
1
3
6
MODEL
Main injectors (mm)
Gas flow rates to main burners
for central heating
Gas valve
Ø 1/2"
G20 - NG G31- LPG
G20 - NG
G31 - LPG
Ø
Ø
m
3
/h
kg/h
FALCON
12x1,30
12x0,77
2,73
2,00
H. V K4105G
MODEL
Gas supply pressures
Gas pressure at main burner for central heating
Safety valve
G20 - NG
G31 - LPG
G20 - NG
G31 - LPG
minimum
nominal
minimum
nominal
mbar
mbar
mbar
mbar
mbar
mbar
bar
FALCON
20
37
2,5
11,8
7,8
36,0
3
MODEL
Domestic hot water
production with
∆
∆
∆
∆
t
30°C
Domestic hot water
production with
∆
∆
∆
∆
t
35°C
Max. working pressure
domestic hot water
Protection
level
Weight
G20 - NG G31 - LPG
l/min.
l/min.
mbar
mbar
kg
FALCON
11,1
9,5
11,8
36,0
IP44
38