59
Parameters
Extended Setting Menu
No.
Name
description
Default value
Other options
20
LANG
Select parameter menu language
“
GB
”
English
“
FR
”
French
21
AIR.S
Display values measured by ambient
sensor
“--.-“
22
OUT.S
Display values measured by floor
temperature sensor (exterior sensor)
“--.-“
23
FL.LI
Setup type of floor temperature sensor
limit:
The parameter permits to select setup
for floor sensor limit
Note: If one of floor sensor limits is
activated, “01” will be displayed in
user menu for the parameter
“-- --“
No floor temperature
sensor limit set
“
LO
--
“
Room sensor with floor temperature
set (lower limit)
“--
HI
"
Room sensor with floor temperature
set (upper limit)
“
LO HI
"
Room sensor with floor temperature
set (lower and upper limit)
24
FL.LO
Lower limit of floor temperature
“
NO
”
Lower limit is not used
From 5˚C to “
FL.HI
“
25
FL.HI
Upper limit of floor temperature
“
NO
“
Upper limit is not used
From
“
FL.LO
“ to 37˚C
26
REGU
Select regulation type
“
PWM
”
Proportionality zone
“
HYS
“
0.5˚C hysteresis (On/Off)
27
T.CY
Select duration of proportionality zone
“
10
“
The value may be increased if