background image

With the light switched on, tap the tail switch to cycle through Low→Med→High→UV.

Battery Specifications 

Type

Dimension

s

Nominal

Voltage

Usability

 

Ni-MH Battery

AAA

1.2V

Recommended

√√

Alkaline Battery

AAA

1.5V

Usable

Lithium Battery

(Non-rechargeable)

AAA

1.5V

Usable

Li-ion Battery

(Rechargeable)

10440/10450

3.7V

Banned

×

Warning: When the voltage level drops below a preset level, the flashlight is programmed to
downshift to a lower brightness level until Low output is reached. To ensure normal use, the
flashlight will not turn off automatically and will work till the battery runs out completely. 

Battery Replacement ②
Unscrew the head to insert the battery with the anode side (+) towards the light head, then
screw the light head back on.

Intelligent Memory Circuit

The light memorizes the last selected brightness level. When turned on again the previously used
brightness level will be recalled.

Time-limited Downshift

The light will accumulate a lot of heat when used on  High  output level for extended periods.
When the light has been used on High for 3 minutes, the light will automatically step down by a
few lumens until 60 lumens is reached to reduce the temperature. High mode can be reselected.

Usage and Maintenance 

Disassembling the sealed head can cause damage to the light and will void the warranty.

Fenix recommends using excellent quality batteries. 

Fenix   strongly   recommends   using  

high-performance   Ni-MH   rechargeable

batteries to get the most out of this light. Alkaline batteries will reduce the
runtime relatively. 

If the light will not be used for an extended period, remove the battery, or the light could be

damaged by electrolyte leakage or battery explosion.

Long-term use can result in O-ring wear. To maintain a proper water seal, replace the ring

with an approved spare

Periodic cleaning of the battery contacts improves the lamp's performance as dirty contacts

may cause the lamp to flicker, shine intermittently or even fail to illuminate for the following

reasons:

A: The battery needs replacing.

  Solution:   Replace   battery  (Ensure   battery   is   inserted   according   to   the   manufacturer’s

specifications).

B: The threads, PCB board contact or other contacts are dirty. 

Solution: Clean the contact points with a cotton swab soaked in rubbing alcohol.