I

USE OF THE 6 ORDER MODE THROUGH THE PILOT CONDUCTOR

If your installation is controlled by the Tempo EDF type controller (French Electrical 
Companies), the decrease of temperature values Comfort 1 or Comfort 2 will be made 
according to the order of this controller in compliance with a tariff season. 
The following 6 orders are in question: Comfort, ECO, Comfort 1, Comfort 2, Anti-Freeze 
Mode and Stop (see the table in Chapter 4). 

x

Comfort 1

 induces the temperature decrease by –1°C in respect of the Comfort 

position. 

x

Comfort 2

 induces the temperature decrease by –2°C in respect of the Comfort 

position. 

NOTES:

- The functions Comfort 1 and Comfort 2 enable to decrease the power consumption 
through the programming centre which carries out a tariff administration according to the 
TEMPO EDF type contracts. 

 - 

As your convector is equipped with an electronic thermostat for 6 orders, 

the changes controlled by the controller and the programming device are not 
immediate; it is necessary to wait for approx. 15 seconds before they are processed

.

x

Exceptional use

:

deviation of the convector from programming 

Regardless the order sent from the programming centre or the controller you can make the 
following settings yourselves: 

 If the room is permanently used, for example by a sick person, it is possible to 

maintain permanently the comfort temperature (set the switch to the Comfort 
position), except the cases when the orders Anti-Freeze Mode or Stop are 
transmitted.

 If the room is not used (for example a guest room), it is possible to maintain the 

temperature at a very low level (the switch is set to the Anti-Freeze Mode position), 
except the case when the order Stop is transmitted.  

In both the foregoing cases, it is necessary to set the switch again to the 

PROGRAMMING position after the exceptional use is cancelled. 

¨

NOTE

: If your installation is equipped with a performance limiter, the limiting is 

a priority; your convector need not heat, although the switch is set to the Comfort position. 

When the limiting is finished, the convector will start heating again. 

Содержание Actua

Страница 1: ...USER S GUIDE ACTUA N162 R01 27 02 07 NATURAL CONVECTION HEATER...

Страница 2: ...ou have just bought this natural convection heater ACTUA manufactured by Air lec Thank you for your choice that proves your confidence It is important to read the entire guide carefully before install...

Страница 3: ...r within the limits of minimal and maximal temperature Min Max OPTIONAL This convector may be equipped with Ecobox2 programming cassettes A687981 A687982 A687983 see the figure beside contact your ven...

Страница 4: ...ard NFC 15 100 This convector of class II is not connected to earth IMPORTANT DO NOT COVER THE CONVECTOR If the convector is covered there is the risk of superheating It is explicitly prohibited to co...

Страница 5: ...etween axes 156mm 156mm 178mm 248mm 320mm 405mm 405mm To carry out this operation it is necessary to remove the bracket from the convector with a screwdriver pressing both the clips Pos 1 Fig C Fix th...

Страница 6: ...conductor from any electrical contact through a terminal box or a domino IMPORTANT In no case connect the black conductor to an earthing clip or a GREEN YELLOW conductor If the supply cable is damage...

Страница 7: ...GEL to maintain an anti freeze temperature in the room x PROGRAMMING PROG enables to accept programmed functional orders 9 SETTING A COMFORT TEMPERATURE x Switch the function switch to the Comfort mod...

Страница 8: ...imensioned properly and the room is closed protected piping in the kitchen or bathroom without condensation When the convector is heated for the first time a bluish vapour can be released which disapp...

Страница 9: ...e programming device are not immediate it is necessary to wait for approx 15 seconds before they are processed x Exceptional use deviation of the convector from programming Regardless the order sent f...

Страница 10: ...tions depend on the convector its position in the room and on the room furnishings If your room is equipped with two convectors the function switches of both convectors must be set in the same way If...

Страница 11: ...nvector the control part and enables to identify your convector The rating plate includes the following data Complete convector references and its serial number pos A must be specified in case of afte...

Страница 12: ...an for which they were intended The warranty shall not cover any damage or accident due to negligence insufficient supervision and or maintenance or modifications of the convector INSURANCE OF PERSONN...

Отзывы: