2. RECOMMENDATIONS 

FOR 

POSITIONING

This convector is usually situated in a place where the heat produced can be mixed with 
the maximum volume of air. 
The convector must be connected in a fixed position according to applicable regulations. 
The convector must be installed in such a way that its switches and other controls are out of 
the reach of any person situated in the batch or under the shower. 

W i r i n g :

W i r i n g   m u s t   a g r e e   w i t h   t h e   r e q u i r e m e n t s   o f   t h e   s t a n d a r d   N F C   1 5 - 1 0 0 .   T h i s   c o n v e c t o r   o f  
c l a s s   I I   i s   n o t   c o n n e c t e d   t o   e a r t h .

¨

 IMPORTANT: “DO NOT COVER THE CONVECTOR”  

If the convector is covered, there is the risk of 
superheating

.

It is explicitly prohibited to cover the 

convector or block the grating where the air enters or 
leaves the convector due to the risk of damage of the 
convector.  
Avoid installing of the convector at a window sill, behind 
curtains, behind a door or under the air suction. Observe 
the minimal installation distances from the floor, the 
walls, the furniture etc. .… (

Fig. B

).  

P r o t e c t i v e   Z o n e

F i g .   A

T h i s  c o n v e c t o r   m a y   b e   i n s t a l l e d  

i n   t h e   z o n e   2   o r   3 ,   i n  

a c c o r d a n c e   w i t h   t h e  

p r o v i s i o n s   o f   t h e   s t a n d a r d  

N F C   1 5 - 1 0 0 .  

Содержание Actua

Страница 1: ...USER S GUIDE ACTUA N162 R01 27 02 07 NATURAL CONVECTION HEATER...

Страница 2: ...ou have just bought this natural convection heater ACTUA manufactured by Air lec Thank you for your choice that proves your confidence It is important to read the entire guide carefully before install...

Страница 3: ...r within the limits of minimal and maximal temperature Min Max OPTIONAL This convector may be equipped with Ecobox2 programming cassettes A687981 A687982 A687983 see the figure beside contact your ven...

Страница 4: ...ard NFC 15 100 This convector of class II is not connected to earth IMPORTANT DO NOT COVER THE CONVECTOR If the convector is covered there is the risk of superheating It is explicitly prohibited to co...

Страница 5: ...etween axes 156mm 156mm 178mm 248mm 320mm 405mm 405mm To carry out this operation it is necessary to remove the bracket from the convector with a screwdriver pressing both the clips Pos 1 Fig C Fix th...

Страница 6: ...conductor from any electrical contact through a terminal box or a domino IMPORTANT In no case connect the black conductor to an earthing clip or a GREEN YELLOW conductor If the supply cable is damage...

Страница 7: ...GEL to maintain an anti freeze temperature in the room x PROGRAMMING PROG enables to accept programmed functional orders 9 SETTING A COMFORT TEMPERATURE x Switch the function switch to the Comfort mod...

Страница 8: ...imensioned properly and the room is closed protected piping in the kitchen or bathroom without condensation When the convector is heated for the first time a bluish vapour can be released which disapp...

Страница 9: ...e programming device are not immediate it is necessary to wait for approx 15 seconds before they are processed x Exceptional use deviation of the convector from programming Regardless the order sent f...

Страница 10: ...tions depend on the convector its position in the room and on the room furnishings If your room is equipped with two convectors the function switches of both convectors must be set in the same way If...

Страница 11: ...nvector the control part and enables to identify your convector The rating plate includes the following data Complete convector references and its serial number pos A must be specified in case of afte...

Страница 12: ...an for which they were intended The warranty shall not cover any damage or accident due to negligence insufficient supervision and or maintenance or modifications of the convector INSURANCE OF PERSONN...

Отзывы: