2. RECOMMENDATIONS
FOR
POSITIONING
This convector is usually situated in a place where the heat produced can be mixed with
the maximum volume of air.
The convector must be connected in a fixed position according to applicable regulations.
The convector must be installed in such a way that its switches and other controls are out of
the reach of any person situated in the batch or under the shower.
W i r i n g :
W i r i n g m u s t a g r e e w i t h t h e r e q u i r e m e n t s o f t h e s t a n d a r d N F C 1 5 - 1 0 0 . T h i s c o n v e c t o r o f
c l a s s I I i s n o t c o n n e c t e d t o e a r t h .
¨
IMPORTANT: “DO NOT COVER THE CONVECTOR”
If the convector is covered, there is the risk of
superheating
.
It is explicitly prohibited to cover the
convector or block the grating where the air enters or
leaves the convector due to the risk of damage of the
convector.
Avoid installing of the convector at a window sill, behind
curtains, behind a door or under the air suction. Observe
the minimal installation distances from the floor, the
walls, the furniture etc. .… (
Fig. B
).
P r o t e c t i v e Z o n e
F i g . A
T h i s c o n v e c t o r m a y b e i n s t a l l e d
i n t h e z o n e 2 o r 3 , i n
a c c o r d a n c e w i t h t h e
p r o v i s i o n s o f t h e s t a n d a r d
N F C 1 5 - 1 0 0 .