background image

- 22 - 

FDM-4000i Manual V1.0 

Gateway Address. Use the Scroll Up/Down menu to select the first number of the desired 
Gateway Address then press the OK button to set. Repeat the process until the Gateway 
Address is completed. Press the OK button to set.



Back to IP Streaming Setup

- Select Back to Main to escape the Web Management   

          Network Setup Menu.

 

 
 
Streaming Setup

 

 



Select  IP  Output 

–  Use  the  Scroll  Up/Down  button  to  enter  the  IP  Output  selection. 

Select IP output port 1 to 4 to set. 



Enable  IP  Streaming 

–  Use  the  Scroll  Up/Down  button  to  enter  Enable  IP  Streaming 

selection. Press OK button to select ENABLE/DISABLE the IP Streaming. 



Streaming Method 

– Use the Scroll Up/Down button to select Streaming Method. Press 

the OK button to  enter the Streaming Method menu. Use the Scroll  Up/Down button to 
select  the  Streaming  Method  required.  Select:  RTP  UNICAST,  UDP  UNICAST,  RPT 
MULTICAST, or UDP MULTICAST. Press the OK button to set.



1

st

  Destination  IP  – 

Use  the  Scroll  Up/Down  button  to  select

 

1

st

 

Destination  IP 

(Address).  Press  the  OK  button  to  enter  the  1

st

 

Destination  IP  Address  menu.  Use  the 

Scroll Up/Down button to set the

 

Destination IP Address. Note:  By selecting Unicast in 

the  Streaming  Method  Menu  the  default  address  begins  at  192.168.1.20.  Use  the  Scroll 
Up/Down button to set the Destination IP Address. Press the OK button to set.  Multicast 
begins at 224.1.1.1.

 

Press the OK button to set.

 

 

 

Destination IP Address Range(s):

 

 

 

Unicast: 0.0.0.0 ~ 223.255.255.255 

 

 

Multicast: 224.0.0.0 ~ 239.255.255.255



1

st

  Destination  Port  Number 

–  Use  the  Scroll  Up/Down  button  to  select  DES  Port 

Number (Destination Port Number). Press the OK button to enter the 1

st

 Destination Port 

Number menu. Use the Scroll Up/Down button to set. Press the OK button to set.

 

For 2 IP Version Only ( 2

nd

 Destination IP / 2

nd

 Destination Port) Functions



2

nd

  Destination  IP  – 

Use  the  Scroll  Up/Down  button  to  select

 

2

nd

  Destination  IP 

(Address).  Press  the  OK  button  to  enter  the  2

nd

  Destination  IP Address  menu.  Use  the 

Scroll Up/Down button to set the

 

Destination IP Address. Note:  By selecting Unicast in 

the  Streaming  Method  Menu  the  default  address  begins  at  192.168.1.21.  Use  the  Scroll 
Up/Down button to set the Destination IP Address. Press the OK button to set.  Multicast 
begins at 224.1.1.2.

 

Press the OK button to set. 



Time To Live 

– Use the Scroll Up/Down button to select Time To Live menu. Press the 

OK  button  to  enter  the  Time  To  Live  .menu.  Use  the  Scroll  Up/Down  button  to  select 
TTL. Press the OK button to set. Default Settings: Unicast: 63. Multicast: 4. TTL Range: 
1~ 255.



Back to IP Streaming Setup

- Select Back to Main to escape the Streaming – IP  

 

   

Streaming Sub Menu.

 

 

Содержание FDM-4000i

Страница 1: ...FDM 4000i Manual V1 0 INSTALLATION CONFIGURATION MANUAL FDM 4000i 4 port SD Digital Modulator with IP...

Страница 2: ...amming and Setup 8 Connecting to the GUI Interface 8 Encoder Programming and Setup via GUI Interface 9 Overview Page of Fenger Encoder 9 Common Setup 10 RF Setup 11 Encoder Setup 12 IP Streaming Setup...

Страница 3: ...y wiring without first disconnecting the unit s power adapter from the device DO NOT connect the power supply to the device if the power cord is damaged DO NOT cut the power cord DO NOT plug the power...

Страница 4: ...tor converts Digital Video Broadcasting DVB standard definition video and audio signals to DVB T The unit features programmable channel and network names Adjustable RF output Normal Inverted and C W a...

Страница 5: ...o 20dB 1dB step Output Impedance 75 Ohm Output Connector F female IP Output Streaming Method RTP UDP Unicast RTP UDP Multicast Output Connector RJ 45 1Gbps Modulation Video Resolution PAL 720x576 25ft...

Страница 6: ...ible UNPACKING and INSPECTION Each unit is shipped factory tested Ensure all items are removed from the container prior to discarding any packing material Thoroughly inspect the unit for shipping dama...

Страница 7: ...the audio source to the red white AUDIO L and AUDIO R INPUT jacks IN1 IN4 Use the red and white jacks for audio input or either one for a single input Repeat this step for each audio source connectio...

Страница 8: ...oder or connect the Ethernet cable to an Ethernet switch Connect an Ethernet Cable to your PC Static IP address A static IP address must be used on the computer you use to configure the Encoder Refer...

Страница 9: ...vice Webpage Overview Page of Fenger Encoder Welcome page showing overview status of the Encoder when fully functioning Step 2 Login Select Common Setup Once the Common Setup Tab is selected you will...

Страница 10: ...ave Notes on Changes Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload and Reboot to the device if only making changes to one parameter of the encode...

Страница 11: ...dulators in an Installation Please ensure each FDM 4000i Modulator has different settings in the categories below if you are installing 2 or more in an installation Output Channel TS ID Network ID Cha...

Страница 12: ...parameters Note There will be an Encoder tab present for each input on the device Step 8 Local Save for each Encoder tab Once all parameters are set you are required to do a Local Save on EACH Encoder...

Страница 13: ...y saved before performing Step 11 Step 11 Upload and Reboot Once you have set all the encoder settings and performed a Local Save for each Setup tab Select Upload and Reboot on the IP Streaming page a...

Страница 14: ...e s IP address Subnet Mask Gateway Enable Disable DHCP and set Host Name Step 13 Save Network Configuration Save Config Once all parameters are set you are required to select Save Config This function...

Страница 15: ...lost Reset to Default Reset all settings back to original factory settings Backup Download all settings of device Upload Upload a saved config file New Password Create and save new password for GUI C...

Страница 16: ...vice Saving your configuration files We highly recommend you to save your encoder configuration files Simply Click the Backup button and the config files will be saved to your computer To upload a con...

Страница 17: ...oder Video Format Program Num Channel Name Provider Name LCN Aspect Ratio Video Output HDCP Audio Input Audio Output Closed Caption Brightness Contrast Saturation Network Setup Streaming Setup Back to...

Страница 18: ...RF data Physical Output Channel Constellation FEC setting OFDM Mode Selection 3 Use the Scroll Up Down button to display IP address Main Menu To access the Main Menu first enter the password by pressi...

Страница 19: ...lt Configuration To reset the Encoder Modulator back to the factory default select the Default Configuration Menu Press OK to enter the Default Configuration Menu Using the Up Down button select YES t...

Страница 20: ...for each character in the desired Network Name A Network Name can consist up to 16 characters Back to Main Select Back to Main to escape the RF Setup Menu Encoder Setup Menu Select Encoder Press the...

Страница 21: ...ress the OK button to set Factory default 128 Sharpness Use the Scroll Up Down button to select Sharpness Press the OK button to enter the Sharpness menu Use the Scroll Up Down button to select the de...

Страница 22: ...address begins at 192 168 1 20 Use the Scroll Up Down button to set the Destination IP Address Press the OK button to set Multicast begins at 224 1 1 1 Press the OK button to set Destination IPAddress...

Страница 23: ...atic IP Address required Subnet Mask Use the Scroll Up Down button to select Subnet Mask Press the OK button to enter the Subnet Mask menu Use the Scroll Up Down button to enter the Subnet Mask Use th...

Страница 24: ...UT VIDEO 2 INPUT VIDEO 3 INPUT VIDEO 4 INPUT DECLARATION OF CONFORMITY Hereby KOSMOSAT SA confirms that the product FDM 4000i SD Digital Modulator with IP conforms to relevant EEC harmonized standards...

Отзывы: