5. Armourer Mode
<<< LB - Previous option
Next option - RB >>>
Foil/Sabre BdyW: When there is a break in the circuit the white
light is illuminated, otherwise the resistance is shown graphically
on the top line. When the circuit is remade it gives you the length,
in milliseconds, of the break. This is useful for detecting small
intermittent breaks in a foil or bodywire. To test the lame wire,
contact the crocodile clip to the foil guard or blade; the green
light will illuminate when there is a connection.
Pressing RB again will open the lame test screen. The resistance
between S3 and S4 is displayed in blocks of 50 ohms. When a
connection is made between the sockets a green light indicates
the resistance is below the FIE limit of 500 ohms and a red light
indicates the resistance is above this limit. If dedicated leads are
not available simply plug in two bodywires, clip one to the lame
and use the other lame clip to probe the lame surface. When a
Epee (weapon): When the tip of a connected epee is pressed the
resistance will be shown in blocks of 10 ohms. If there is a guard
short it will display which wire (or both) is shorting. If pressing the
epee tip does not register, press the tip against S4 (or the pin of a
connected bodywire). If nothing happens then there is no
connection from either wire, otherwise the resistance of each
wire is displayed on separate lines.
Spool/Grnd Wire: This displays the resistance between the three
sockets on the left to the three sockets on the right in 10 ohm
blocks. On the bottom line it counts the numbers of breaks in
each connection. The breaks total can be reset to zero by pressing
RB. This can be used to test bodywires, ground wires and spools.
Intermittent faults can be located by moving the cables/spools
and checking the number of breaks.