Overvoltage protective equipment – lightning diverter

To prevent from damages caused by lightning, we recommend leading a circuit of fence sys-

tem near to building via overvoltage protective equipment – lightning diverter fastened to 

outer masonry of the building by means of non-combustible materials before its connec-

ting to energizer. This applied also for combined energizers, if they are used together with  

a network adapter. 

Overvoltage caused by storm can cause insulation of 

electric fence system. In such a case, network voltage 

can get into electric fence system, and serious danger to 

people or animals can occur.

Avoid direct contact with fencing, especially with head, neck or upper part of body. Do not 

creep through the fencing or over it. For passing the fence system, use a gate or another point 

in installation designed for this purpose. 

Generally, we recommend connecting network powered electric fence system only to such 

supply networks that are protected with earth-leakage circuit breaker with maximum actua-

ting current of 30 mA. In addition to that, correct installation of energizer with auxiliary dis-

charger and choking coil is necessary, as described within these instructions. It is suitable to 

disconnect network supplied electric fence system from network as well as from fencing (if 

possible) during storm.
If a network with earth-leakage circuit-breaker was not used for purposes of supplying ener-

gizer, and the enrgizer was connected to the fence system or the network during storm, it 

is necessary to check and test it before putting it into operation again. For this purpose, co-

nnection to network with earth-leakage circuit-breaker must be available. For purposes of 

testing, connect earthing output of energizer to protective conductor of the supply network 

and connect pin to power socket protected with earth-leakage circuit-breaker then. If ener-

gizer beats correctly and does not show any deviations from normal operation subsequently, 

it can be connected to fence system again. If the earth-leakage circuit-breaker however falls 

out when energizer is connected, you must not use it and it must be repaired professionally 
If connecting lines of this energizer are damaged, they must be replaced by manufacturer or 

authorized service or another qualified person so that possibility of danger is excluded. Servi-

ce and repairs of these energizers must be performed by authorized persons only! Each user 

of electric fence system is responsible for its operation and should perform regular checks of 

energizer and fence system at least once a day, depending on operating conditions!
Procedure of checking:

•  Visual control of energizer and fence system

•  Measuring of minimum voltage of 2500 V in every place of the fence system

If installation is performed inside a building, energizer may not be operated in a room with 

increased risk of fire in any case (barn, shed, cattle shed). In addition to that, no combustible 

materials may be stored near to fence system and connectors of energizer. Installation of ener-

gizer must be made on a fire-resistant surface. 

For stable using, use only energizers designed for that purpose!

Содержание power DUO PD10

Страница 1: ...DUOPD50 7 5 J 5 J 11 000V 6600 V fencee power DUOPD70 10 J 7 J 10 500V 7500V 35 km 8 km 2 km 1 5 km 60 km 15 km 3 km 1 5 km 100 km 23 km 5 km 2 km 120 km 30 km 8 km 3 km 140 km 40 km 10 km 4 km 180 k...

Страница 2: ...nics s r o Dvorsk 605 563 01 Lan kroun Company ID No 64793826 declares that the below listed products are in accordance with requirements of standards and regulations relevant for given type of device...

Страница 3: ...ny ID No 64793826 declares that the below listed products are in accordance with requirements of standards and regulations relevant for given type of devices Products are safe under condition of their...

Страница 4: ...ics s r o The equipment conforms to safety regulations in accordance with valid legislation as well as relevant EU CE regulations We also ask you to read these instructions for use before using the de...

Страница 5: ...amage to the fence system Use only the original adapter to supply the energizer 14 V 1 A The supply voltage must not exceed 16 V 12 V controller must be used if the solar panel is used as the energize...

Страница 6: ...lasts for a matter of milliseconds These fences serve not only to enclose an area but also act as a dete rrent e g to protect against wild boars Benefits of electric fence systems Electric fences are...

Страница 7: ...on and optimal performance 3 years warranty Czech product 5 2 List of main advantages 5 1 Energizers PD with power output higher than 5 J Standard s special requirements must be observed for energizer...

Страница 8: ...0 V mains or standard 12 V battery which may also be used as the backup power supply Time delay 50 s Increase power to maximum power for safety reasons LED Bargraph Provides visual information on fenc...

Страница 9: ...mounting bracket Set for assembly on DIN rail can be ordered as separate accessories 7 READY TO USE Choose a place suitable for installation of energizer Where you can achieve a good earthing Which is...

Страница 10: ...is recommended Distance of at least 10 metres must be between earthing rod of fence system and another earthing system for example earthing of a house protective earthing of electric supply system or...

Страница 11: ...power failure Running the energizer for a long time just from the battery is not desirable due to the higher energy consumption and low capacity of conventional batteries Connecting output terminals C...

Страница 12: ...ff 9 EXPLANATION OF LED INDICATING LIGHTS AND BARGRAPH INDICATOR LED control BURNING BLINKING blinking operation on battery only permanent burning operation with adapter COLOR blue operation at higher...

Страница 13: ...e electric fence system must not be powered by two or more energizers or by independent power supply devices designated for electric fence systems of the same equipment When operating two or more diff...

Страница 14: ...ondu ctors of the power line on the ground surface for a distance of 2 m for power lines operating at a nominal voltage not exceeding 1000 V 15 m for power lines operating at a nominal voltage exceedi...

Страница 15: ...e system or the network during storm it is necessary to check and test it before putting it into operation again For this purpose co nnection to network with earth leakage circuit breaker must be avai...

Страница 16: ...able is recommended Conductor has adverse properties thin diameter high resistance Use high quality conductor with low resistance and larger diameter Ensure high quality correct connection of conducto...

Страница 17: ...cts or manufacturing defects shall be removed in manufacturer s discretion by repairing or free of charge replacement of the energizer In case of delivering spare parts or repairing original guarantee...

Страница 18: ...0 V 12 000 V 11 200 V OUTPUT VOLTAGE 500 5000 V 6000 V 6400 V ON OFF LED ON OFF LED IMPULS LED LOW BATTERY VOLTAGE LED POWER LOWER 50 LED ERROR CHECK LED IMPULS BARGRAF TEOR MAX CEE 35 km 60 km 100 km...

Страница 19: ...VOLTAGE 10 000 V 11 000 V 10 500 V OUTPUT VOLTAGE 500 5500 V 6600 V 7500 V ON OFF LED ON OFF LED IMPULS LED LOW BATTERY VOLTAGE LED POWER LOWER 50 LED ERROR CHECK LED IMPULS BARGRAF TEOR MAX CEE 120...

Страница 20: ...nics s r o Dvorsk 605 563 01 Lan kroun Czech Republic info fencee eu 420 730 893 828 Customer Service 420 730 893 827 fencee cz fenceeczech Electric fencing www fencee eu www fenceefarm com Stamp and...

Отзывы: