8. CONTROL
IN SWITCHED-OFF CONDITION OF THE ENERGIZER
Compared to POWER models, the ON/OFF switch button has extended functionality here. Af-
ter first switch-on of energizer, blue LED is burning or blinking indicating operation at higher
output. After each other switch-on, the energizer remembers selected mode.
IN SWITCHED-OFF CONDITION OF THE ENERGIZER
Long press (>2 s)
Energizer is switched on.
Short press
No response.
ENERGIZER IS SWITCHED ON; BY PRESSING PUSH BUTTON:
Long press (>2 s)
Manual switching between the high and low power out-
put (approximately 50 %).
User selectable; when, for example, it is used for more
sensitive animals or to reduce demand on battery, if required. The low power output is
always limited to the maximum of 5 J.
Short press
Energizer is fully switched off.
9.
EXPLANATION OF LED INDICATING LIGHTS AND BARGRAPH INDICATOR
LED control:
BURNING / BLINKING
•
blinking
operation on battery only
•
permanent burning
– operation with adapter
COLOR
•
blue
operation at higher output (100%)
•
purple
operation at lower output (c. 50%)
•
red
it lights up when battery voltage drops below 12 V.
When battery voltage drops below 11,6 V, warning siren is started (beeping). When battery
voltage drops below 11,4 V, energizer is switched off. Reason is protection of battery from
deep discharge of the battery (battery destruction). If discharged battery and adapter are
connected simultaneously, red LED is burning, until battery is charged at 12 V at least.
BARGRAPH INDICATOR:
To indicate input voltage at fence system,
power DUO PD
models are equipped with
BARGRAPH indicator. It consists of six
LEDs - 2× RED
I
2× YELLOW
I
2× GREEN
– ordered
from left to right. BARGRAPH indicator always goes through LEDs from the first red one up to
indicated position where it stops for a while.
–
–
–
–