![Fema MAG983 Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/fema/mag983-series/mag983-series_user-manual_3944649002.webp)
FEMA ELECTRÓNICA - Page 2
User¨s Manual - Series MAG983-X
The MAG983-X is a series of impulse counters with 6
digits for panel mounting. The main input channel for
impulse counting is defined as «INPUT1», and the
additional input channel defined as «INPUT2» has a
variable function depending on the model selected. All
units can «RESET» from frontal push button and also
from rearside terminal for mechanical contact.
Series
MAG983-X
Impulse COUNTERS
Model MAG983-1
Impulse counter with Inhibit Control
«INPUT1» Input for impulses
«INPUT2» Control for Inhibit
Note .- «INPUT2» at negative logic, activates inhibit
Model MAG983-3
Impulse counter with Add/Substract inputs
«INPUT1» Impulses to ADD
«INPUT2» Impulses to SUBSTRACT
Model MAG983-2
Impulse counter with Add/Substract control
«INPUT1» Input for impulses
«INPUT2» Control for ADD/SUBSTRACT
Note .- «INPUT2» at negative logic SUBSTRACTS
Model MAG983-4
Impulse counter for Quadrature (Encoder)
«INPUT1» Impulses from encoder CHANNEL-A
«INPUT2» Impulses from encoder CHANNEL-B
The reading of the instruments can be scaled activating
scale factors, together with the position of the decimal
point. By default, all units are configured as :
1 impulse = +1
Signal type NPN
Without decimal points
If a different configuration is needed, request your needs
with the order, or see instructions on section 8 for self
configuration.
0.- Ordering Reference ____________________________________________________
1.- Technical Data________________________________________________________
DISPLAYS
Led 7 segments red color
SEGMENTS
9.9.9.9.9.9
DIGIT HEIGHT
14,2 mm. (0,56")
POLARITY
negative counting indicated by LED
READING
from 0 to 999999
DECIMAL POINT
6 positions, factory selected
(or see section 8)
INPUT SIGNAL
PNP,NPN,Namur,Contact, Pick-Up
Jumper selectable
maximum 28Vdc at input
PICK-UP Data
only on «INPUT1»
Sensibility 150 mV peak
Hysteresis 100 mV
Impedance 26.5 Kohms at 60 Hz
Maximum input voltage ±50 Vpp
RESET
Contact at rearside terminals
Frontal push button
Vexc OUTPUT
+10Vdc (maximum 70 mA)
FREQUENCY
maximum up to 10 KHz
MEMORY
E
2
Prom non volatile
ON/OFF CYCLES
100.000 minimum
DATA RETENTION
10 years minimum
TRIGGER LEVELS
Selectable
(See section 4)
«0» < 1.50 Vdc or «0» < 5.50 Vdc
«1» > 3.75 Vdc or «1» < 7.50 Vdc
POWER
230 Vac (50 Hz)
CONSUMPTION
3VA
EXTERNAL FUSE
50 mA at 230 Vac (not incluided)
CONNECTIONS
Plug-in screw clamps
WIRE SECTION
max. 2.5 mm2 (recommended1mm
2
)
WORKING TEMP.
from 0 to +50 ºC
STORAGE TEMP.
from -40 to +70 ºC
RELATIVE HUMIDITY
90 % a 40°C
HOUSING
DIN 43700
DIMENSIONS
96 x 48 x 117 mm (3,78 x1,89 x 4,61’’)
PANEL CUTOUT
92,5 x 44,5 mm (3,64 x 1,75‘’)
MATERIAL HOUSING
ABS, black color
WEIGHT
310 gr.
Model
Power
Signal Type
Counting Relation
Decimal Point
MAG983
1
230 Vac
NPN
1 imp = +1
x x x x x x
2
PNP
1 imp = +2.5
xxxxx
.
x
3
Namur
1 imp = +0.1
xxx
.
xxx
4
Pick-Up
...
Mechanical