background image

SERIES 

I3

 · Model 

I3D

USER’S MANUAL

ISOLATED

SIGNAL

DUPLICATOR

Section OEM

5577r03

Process

0/10 Vdc

Process

4/20 mA

OEM

YOUR CONVERTER !

APPLICATIONS

www.fema.es

Duplicator

Process

Double

Содержание I3 Series

Страница 1: ...SERIES I3 Model I3D USER S MANUAL ISOLATED SIGNAL DUPLICATOR Section OEM 5577r03 Process 0 10Vdc Process 4 20mA OEM YOURCONVERTER APPLICATIONS www fema es Duplicator Process Double...

Страница 2: ...3 7 Technical specifications 3 8 Connections and dimensions mm inch 4 9 Access the Configuration system 6 10 Operate theconfiguration system 7 10 1 Normal mode of operation 7 10 2 Configuration mode 7...

Страница 3: ...mA active max 20 5mA min 3mA maximum load 400Ohm passive 4 20mA output 4 20mA passive max 30Vdc on terminals OUTPUT SIGNAL2 active 4 20mA output 4 20mA active max 20 5mA min 3mA maximum load 400Ohm pa...

Страница 4: ...on device Use time lag fuse with value 250 mA for voltages 50Vac dc 400 mA for voltages 50Vac dc fuse output 4 20mA passive current out output 4 20mA current in output 4 20mA active current out POWER...

Страница 5: ...c The instrument has two outputs output1 is fixed to 4 20 mA active and passive output2 is fixed to 4 20 mA active and passive To select the active or passive mA versions at the input and output signa...

Страница 6: ...operations must be performed by qualified operators When correctly connected the input signal terminal prevents the front cover from opening ACCESS THE CONFIGURATION SYSTEM Step numbers as referenced...

Страница 7: ...eypad is located inside the instrument behind the removable front cover To access the configuration keypad remove the input signal terminal and open the front cover see section 9 The instrument allows...

Страница 8: ...and return to the Force high Fh menu entry Table 6 Tools menu UP Press UP 5 for 1 second to access the tools menu Force Low Force high Exit 9 Operate theconfiguration system cont HOWTO BLOCK ACCESSTO...

Страница 9: ...rovalves together with signal and or control cables Before proceeding to the power connection verify that the voltage level available matches the power levels indicated in the label on the instrument...

Страница 10: ...fixed to 3mA Possible shortcircuit at input Possible open circuit at input E4 Overload at the 4 20mA input The input signal detected is higher than 90mA The instrument self protection has opened the c...

Страница 11: ...SERIES I3 Model I3D Section OEM ISOLATED SIGNAL CONVERTERS www fema es 11 Notes...