FEMA ELECTRÓNICA . SERIES B . Models Bxx-T
8
Digits
number of digits
4
digit
7 segments
view angle
120º
color
red or green
digit height
Reading
max., min.
9999 / -1999
overrange / underrange flash reading
sensor break
reading to maximum or mini
-
Input signal
accepted signals
Pt100 / RTD and thermocouples
temperature scale
ITS90
units
ºC or ºF
wire section
max. 0.5 mm
2
Pt100 / RTD signals
2 or 3 wire, selectable
resolution
1º or 0.1º, selectable
measuring ranges
max. error at 25 ºC
thermal drift
cable res. compensation automatic, up to 14 Ohms
compensation error
<0.02 ºC / Ohm
readings
4 / second
Thermocouples
J, K, T, E, S, R, N, C, L, X*
(*thermocouple X is a lineal 10 uV / ºC signal)
resolution
1º
measuring ranges
max. error at 25 ºC
thermal drift
thermocouple CJC
automatic
CJ accuracy
<1.0 ºC
CJ thermal drift
<0.04 º/ºC
readings
3 / second
Functions included
Section
Fast access menu
yes, configurable
Manual offset
configurable
Thermocouple cold
junction
configurable
Probe break detec-
tion
configurable
Display filters
‘steps’
‘On Power Up’
yes
Alarms
simple or double setpoint
activation delays
deactivation delays
hysteresis
inverted relays
locked alarms
Memory
maximum, minimum
Password
configuration locked
Brightness
configurable, 5 levels
Table 9 - Functions included
The 4 pin terminal located beside
the input signal module allows to
replicate a remote version of the
front keypad. Connect 4 cables for
front keys ‘SQ’ (
<
), ‘UP’ (
5
) and
‘LE’ (
3
) and for the common. Pass
these cables through the ‘remote
keypad’ cable gland
GND
SQ
UP
LE
1.9
Connections for remote keypad
1.10
Functions included
Messages and errors
.
‘h.oVr’
hardware overrange (‘
h.ovr
’). Input signal is high
-
er than 80 mV.
‘h.udr’
hardware underrange (‘
h.udr
’). Input signal is
lower than -30 mV.
‘d.udr’
‘d.oVr’
display underrange (‘
d.udr
’) / overrange (‘
d.ovr
’).
The display is displaying the maximum / mini
-
mum value possible (-1999 / 9999).
Table 10 - Messages and error codes.
Messages and errors
.
‘brk’
instrument displays ‘brk’ ‘9999’ or ‘-9999’
• measured Pt100 resistance is higher than
390 Ohms (higher than 850 ºC)
• the Pt100 third wire has a measured impedance
higher than 15 Ohms
• the thermocouple is open circuit
‘Err.1’
incorrect password.
‘Err.2’
at ‘
oPt.X
’ menu entry, module is not recognized.
Table 10 - Messages and error codes.
1.11 Messages and errors
1.12
Technical specifications