background image

6

COL

OUR

 

INDIC

A

TION

MENU FEA

TURE

HO

W T

O A

CCESS

S

AFE CLEANING

 

MODE

This feature allows you to clean your control and mix

er

 

without turning on your mix

er during cleaning.

PRESS & HOLD

 the control for 5 seconds until the GREEN light a

ppears, then release.

This will disable the control for 45 seconds to allow the control to 

be cleaned without 

turning on.

To cancel, press the control again.

PLEA

SE NO

TE THERE IS A DELA

Y BETWEEN THE 'S

AFE CLEANING MODE' AND 'DIA

GNOS

TIC TES

T' — PLEA

SE DO NO

T RELEA

SE PRESSURE

DIA

GNOS

TIC TES

T

This feature will run a series of diagnostic checks with

 

lights indicating if your control is OK or malfunctioning.

Please see troubleshooting page in the Installation Guide

 

if error occurs or contact the Felton T

echnical T

eam on

 

0800 743 358.

PRESS & HOLD

 the control for 18 seconds until ORANGE light appears,

then release.

A series of lights will flash to indicate which stage the diagnostic is checking.

To cancel, press control again

.

COL

OUR INDIC

A

TOR

RED LIGHT

 V

alve is hot

GREEN LIGHT

V

alve is off

BL

UE LIGHT

V

alve is cold

LIGHT OFF

System check complete

THE FUNCTIONS BEL

O

W ARE ONL

Y AD

JUS

TABLE FOR 

1 HOUR

 AFTER INITIA

TION

CONSUL

T FEL

T

ON RECOMMENDED INS

TALLER UPON INS

TALLA

TION

MAXIMUM

 

TEMPERA

TURE

This feature allows you to adjust to your desired maximum

 

temperature to avoid accidental scalding, especially for

 

the elderly and children.

Maximum temperature on default is 45°C.

PRESS & HOLD

 until light starts flashing WHITE.

R

elease immediately to access.

 

TURN

 to adjust desired maximum temperature.

PRESS

 again to save maximum temperature.

Maximum default temperature is 45ºC.

THERMAL

 

DISINFECTION

This feature flushes out the pipes at the hottest

 

temperature your system will allow

. This will clean

 

through any limescale and clear any potential bacteria.

Note:

 If your thermal disinfection indicates a red light at the 

end of the disinfection, your system has not provided hot 

water greater than 55ºC. This can be ignored as it does not 

affect the function of the thermal disinfection process.

 A

TTENTION: RISK OF SCALDING

PRESS & HOLD

 for appro

x 20 sec until light starts flashing RED

.

Release immediately to access.

Flashing RED:

 Thermal disinfection flushes out hot water

.

A

utomatic stop after 2 minutes. RED flashes.

Press again to finish thermal disinfection.

 

To stop disinfection during cycle:

 PRESS ONCE.

RES

TORE

FA

CT

OR

Y SETTINGS

This restores all settings back to the original default

 

settings ex

cept for flow memory.

PRESS & HOLD

 until light starts flashing BL

UE.

Release immediately to access.

Flashing BL

UE twice:

 Factory setting is restored.

MAXIMUM W

A

TER

FL

O

W TIME

This water saving feature allows you to set the unit to

 

switch off automatically after a maximum run time. Y

ou

 

can set the maximum from 5 seconds to 30 minutes.

 

PRESS & HOLD

 until light starts flashing PINK.

Release immediately to access.

 

PRESS

 to set desired water flow time

Flashing PINK twice:

 Setting is saved.

HY

GIENE

FUNCTION

This feature is used for setting up the shower to turn on

 

and regularly flush the system through. The complete

 

flush will automatically stop after 2 minutes.

Note:

 If your thermal disinfection indicates a red light at the 

end of the disinfection, your system has not provided hot 

water greater than 55ºC. This can be ignored as it does not 

affect the function of the thermal disinfection process.

PRESS & HOLD

 until light starts flashing YELL

O

W

.

Release immediately to access.

PRESS ONCE

 to adjust interval flushing at the number of flashes.

Flashing YELL

O

W twice:

 Setting is saved.

FLA

SHES

1st

2nd

3rd

4th

5th

TIME

1 day

2

 days

3

 days

days

Inactive

AMBIENT LIGHT

 

SETTINGS

This feature is used for setting up the display light when

 

the system is off

.

PRESS & HOLD

 until light starts flashing LIGHT BL

UE.

 

Release immediately to access.

  

 

PRESS ONCE

 to choose the desired colour

Flashing BL

UE LIGHT twice:

 Setting is saved

IMPOR

TANT

: Once powered up

, the control must be programmed within one hour

.

If the activation set up is not complete within one hour

, power off the unit, leave it for 20 minutes, then restart agai

n.

AD

V

ANCED A

CTIV

A

TION SET UP

To access each setting, PRESS & HOLD until colour changes in 

the order shown

, then release to access desired menu setting.

Malfunction of the 

temperature sensor

.

Please contact Felton 

Technical T

eam on

0800 743 358.

3 x 

ORANGE

 flashes

2 x 

ORANGE

 flashes

The control unit is OK.

Содержание TATE

Страница 1: ...USER GUIDE TATE Digital Mixer...

Страница 2: ...ged or after any malfunctions WARNING Continuously turning the control dial in the clockwise direction may override the preset maximum temperature with consequent risk of scalding Always take care whe...

Страница 3: ...shooting 10 Warranty 11 Finishes and care 9 Safety information 2 The Tate Digital Wall Mounted Mixer and the Tate Digital Deck Mounted Mixer have a fixed flow rate i e no flow adjustment function If y...

Страница 4: ...ight will turn off To turn OFF Turn the dial anti clockwise the control will illuminate blue and will flash until the set temperature is reached Turn the dial clockwise the control will illuminate ora...

Страница 5: ...FLOW MEMORY Turn to set desired temperature Colour should change Adjust flow by holding and turning the dial PRESS HOLD the dial to save Once the purple light flashes release immediately Default temp...

Страница 6: ...again COLOUR INDICATOR RED LIGHT Valve is hot GREEN LIGHT Valve is off BLUE LIGHT Valve is cold LIGHT OFF System check complete THE FUNCTIONS BELOW ARE ONLY ADJUSTABLE FOR 1 HOUR AFTER INITIATION CON...

Страница 7: ...PRESS HOLD until light starts flashing PINK Release immediately to access PRESS to set desired water flow time Flashing PINK twice Setting is saved HYGIENE FUNCTION This feature is used for setting u...

Страница 8: ...sed to chrome plate our tapware The tap bodies are sealed in an airtight chamber and a vacuum is created In this vacuum an inert gas such as nitrogen is used as a medium and the negatively charged tap...

Страница 9: ...a soft microfibre cloth with a solution of warm water and mild detergent to wipe down the mixer once a week to keep your tapware and mixers looking great Things to avoid Avoid abrasive cleaning solut...

Страница 10: ...will not turn off Carry out function Diagnostic Test in User Guide The water shuts off before maximum run time has been reached Flow sensor is defective Carry out function Diagnostic Test in User Gui...

Страница 11: ...ligence or improper installation This warranty is given on the understanding that the product is installed by a registered plumber and operated according to Felton s installation guide and the Austral...

Страница 12: ...felton industries limited FeltonIndustriesLimited feltonltd feltonltd feltontapware FELTON INDUSTRIES LTD 8 Farmhouse Lane St Johns Auckland 1072 w w w felton co nz Find us on Social Media 130521HM...

Отзывы: