background image

8

Fast

or 

Slow

key. To return to the 2-second average the instrument

must be switched off and on again. 

Error indication

If the display shows 

E.xx

when switching on or during operation, this

indicates a fault. The fault can be identified from the E-number details
under Technical Data in chapter 5.

Measurement

When it is safe to measure the air speed, the measuring head is held
against the felt, above the slit of the Uhle
box. The slit in the measuring head should
be in contact with the felt, the round hole
should be ‘on top’. 
By rotating the measuring head a few deg-
rees clockwise and counter clockwise one
will see that the measured air flow will vary.
There is no rule of thumb for the right
angle; it depends on felt weight and water
content, felt speed, width of the slit and the
force with which the measuring head is pressed onto the felt. Generally
spoken the position which gives the highest test results is the best. 

After switching on the instrument, averages are calculated over 2
seconds (every 0,5 second a value). Pressing the 

Min/Max

key will

return the minimum and maximum test results measured. Pressing the

Flow

key will return to the current test values.

Where greater accuracy is required and the flow is rather irregular the
test time can be extended, resulting in an average over 6 seconds
(press the Fast key) or 22 seconds (press the 

Slow

key). During the

measurement the remaining test time up to the end is indicated in
seconds. The 

Mean

or average value of the complete measuring cycle

will be calculated when the measuring time has ended. A new meas-
urement is started by pressing the 

Fast

or 

Slow

key again. To return to

the 2 second average, the instrument needs to be switched off and on
again.

When the display shows 

BATT

the battery (9 Volt) has to be replaced.

Содержание AirSpeed/2

Страница 1: ...Instruction manual Feltest AirSpeed 2...

Страница 2: ...2...

Страница 3: ...2 1 Intended use 4 2 2 Safety precautions 4 3 About the instrument 6 3 1 Names of parts 6 3 2 Working principle 7 4 The measurement 7 4 1 Measuring procedure 7 4 2 Interpretation of the results 9 5 T...

Страница 4: ...Feltest Equipment bv for more information Keep this manual where the operator can easily find it Use the instrument as intended and according to this manual Do not measure the airflow through forming...

Страница 5: ...fety constructions from the paper machine Please note Doing measurements of any kind on running paper machines is dangerous and requires alertness concen tration and common sense The Feltest instrumen...

Страница 6: ...f an electronic read out unit a probe with a small propeller that is installed in a plastic measuring head and a telescopic grip The air flow is measured by a small aerody namically optimised propelle...

Страница 7: ...e air speed through a press felt Find a safe and stable position close to the Uhle box expand the telescopic grip so it will not be necessary to bend over into the machine but most important is to sta...

Страница 8: ...ith which the measuring head is pressed onto the felt Generally spoken the position which gives the highest test results is the best After switching on the instrument averages are calculated over 2 se...

Страница 9: ...several measurements over time with different levels of vacuum one could calculate a relative dynamic permeability This means to meas ure both vacuum and air speed and then calculating the air speed...

Страница 10: ...Display LCD 4 characters Measuring rate 2 values sec Supply Battery 1 x 9 Volt size PP3 Current consumption approx 15 mA Battery life approx 12 hours Case dimensions 80x145x39 mm ABS plastic Case pro...

Страница 11: ...1989 The evaluation procedure of conformity was assured according to the following standards a Emission EN 55022 1994 b Immunity EN 50082 1 1992 This EC Declaration of conformity is based on the test...

Страница 12: ...P O Box 205 NL 6960 AE Eerbeek The Netherlands T 31 313 652 215 F 31 313 654 068 E info feltest com W www feltest com...

Отзывы: