background image

 

 

How to replace a hot-end nozzle 

29 January 2021

 

 

FELIX

 Pro  

www.FELIXprinters.com  

Pro series 

 

7

 

Reconnect the hot-end to its cables  

Put the cables into their slots again and carefully lock them with the small screws. Check that the cable 
goes to the right side away from the handle. 

Do not put too much pressure on the thermistor and heater but just 

enough to feel the cables are locked in their places. 

 

8

 

Put the hot-end back into its slot 

Firmly push the hot-end into its slot. Make sure it is pushed in all the way to the back. Push till you hear a 

‘click’ sound. This means the hot

-end is in the correct position. 

 

5.

 

Pull off edge connector of corresponding print head, do NOT pull the wires, there is also a small hook on 
the fan duct to which the cable is fixed take it off this hook first. 

6.

 

Open the cover in front.  

7.

 

Rotate slightly to right  

8.

 

and Then pull out print-head 

9.

 

Reverse the assembly of the hot-end into the extruder assembly. Do not forget to close the lid. 

IMPORTANT: Ensure the hot-end wires make the bend as shown in picture above

 

10.

 

Please do the following two extruder calibrations, if you wish to properly print with dual head. 

-

 

Z-height calibration 

-

 

XY calibration 

 

2

 

4

 

3

 

1

 

 

Отзывы: