Felisatti VC25/1400 Скачать руководство пользователя страница 7

6

 

Do not leave the device without supervision. In case of longer 
interruptions of work, pull the power plug.

Warning!

 

Have repairs been made only by experts, e. g. the producer’s 
service. Use original spare parts only.

 

Improperly repaired devices pose a hazard for the user.

2 Before use.

When unpacking, check that the unit is complete and shows no 
signs of transport damage.
Read all the information carefully. They contain important advice 
about how to use the unit, safety, maintenance and care. Please 
keep these operating instructions somewhere safe and pass on 
to any subsequent owners. We reserve the right to make design 
and equipment changes.

3 Fields of application

 

The vacuum device is designed for industrial use. Ideal in 
combination with an electric tool, on building sites, in work-
shops, etc. For wet and drying suctioning.

4 Commissioning.

Switch the unit ON/OFF with the switch 

a in the top section 

 

(or switch to automatic mode – see Section 4.1.).

4.1 

Operating ield.

Depending on the unit coniguration, the following functions and 

settings are available:

0

 = Suction unit >off<

I

 = Suction unit >on<

= Ready mode for ON/OFF automatic mode. (Suction unit is 

switched ON/OFF by the electrical tool)

R

 = Filter cleaning function; in this switch setting the vibrator 

is activated for approx. 10 sec. and then switches off again 
automatically.

RA

 = Ready mode like “A” plus automatic ilter cleaning.

The power socket 

b is available for connecting an electrical

tool.

Caution!

The electrical tool must be switched off during connection. The 
power socket is permanently supplied with voltage when the plug 
is in the mains socket regardless of the switch setting. In switch 
setting “0” the power socket could still be used as an extension 
cable (e.g. for lights).
Connected load: Suction unit and connected unit max. 16 A. 
The suction output can be adjusted steplessly using the rotating 
speed setter 

d.

The suction openings of the electrical tools are not standardised. 
There is an adapter available (rubber nozzle or rubber muff) 
which can be shortened and adjusted to the respective electrical 
tool.

5 Operation [wet and dry suctioning]

When the handle pipe is used, the secondary air valve can be 
used to adjust the suction output.

5.1 Dry suctioning.

Only suction with a dry ilter, unit and accessories so that the 

dust does not adhere and harden. We recommend using a paper 

ilter bag if soot, cement, plaster, lour or similar substances are 

suctioned. Always use the paper ilter bag in combination with the 

ilter cartridges.

5.2 Wet suctioning.

Suction without a paper ilter bag. The ilter cassettes are suitable 

for wet suctioning.
The installed sensor switches the motor off when the tank is 
full. Empty the unit as outlined in Section 5.4. If the unit is not 
switched off, the restarting safeguard remains effective. The unit 
will only be ready for operation again after it has been switched 
off and switched on again.

 

Before emptying, irst remove the suction hose from the 

liquid.

 

Due to the high suction output and the streamlined shape of 

the tank, a little water may escape from the hose after the 
unit has been switched off.

Содержание VC25/1400

Страница 1: ...ru uborka pylesosy promyshlennye_stroitelnye felisatti universalnyi_pylesos_f elisatti_vs50_1400_3211001000 http www vseinstrumenti ru uborka pylesosy promyshlennye_stroitelnye felisatti universalnyi...

Страница 2: ...ss und Trockeneinsatz Vacuum cleaner for wet and dry applications Aspirateur eau et poussi res Aspirador de material h medo y seco Aspiratore di solidi e liquidi Aspirador para zonas secas e h midas V...

Страница 3: ...2...

Страница 4: ...3...

Страница 5: ...4...

Страница 6: ...n the instruction manual In case of any inappropriate usage improper operation or repair the producer shall be exempt from liability Do not use any damaged extension lines If the connector line of the...

Страница 7: ...aution The electrical tool must be switched off during connection The power socket is permanently supplied with voltage when the plug is in the mains socket regardless of the switch setting In switch...

Страница 8: ...outside through the suction pipes to the inside again 5 5 2 Exchanging the paper ilter bag Carefully pull the lange from the suction connections and close the lange Turn on the motor before putting do...

Страница 9: ...t Watt 1200 1200 mx output Watt 1400 1400 frequency Hertz Hz 50 60 50 60 air low m h MG 220 220 low pressure hPa MG 248 248 air low m h SE low pressure hPa SE sound pressure dB A 69 5 69 5 l x b x h c...

Страница 10: ...uperior a 60 C De lo contrario existe peligro de explosi n e incendio Peligro Utilice la caja de enchufe disponible en el aspirador exclusivamente para los ines establecidos en el manual de instruccio...

Страница 11: ...tico el aspira dor se enciende y apaga con la herramienta el ctrica R Funci n de limpieza del iltro en esta posici n se pone en marcha el vibrador durante aproximadamente 10 segundos y se apaga despu...

Страница 12: ...tros Colocar el reborde sobre el oriicio de aspiraci n 5 5 2 Cambiar el iltro de papel Extraer con cuidado la brida de la apertura de aspiraci n y cerrar herm ticamente Conectar el motor antes de term...

Страница 13: ...00 VC50 1400 Tensi n Volt V 220 240 220 240 Potencia nominal Vatio 1200 1200 Potencia m x Vatio 1400 1400 Frecuencia Hertz Hz 50 60 50 60 Corriente de aire m h MG 220 220 Bajopresi nk hPa MG 248 248 C...

Страница 14: ...de l essence de l huile de l alcool du diluant ou des mati res plus chaudes que 60 C Risque d explosion et d incendie si ces conditions ne sont pas respect es Danger Utiliser la prise igurant sur l a...

Страница 15: ...es chantiers dans les ateliers etc Pour aspirer mouill et sec 4 Mise en service Mettre l appareil en hors marche avec l interrupteur a se trouvant sur la partie sup rieure ou le commuter en mode autom...

Страница 16: ...le lexible d aspiration du contenant Vider le contenant 5 5 Filtre en papier Pour mettre en place ou retirer le iltre le iltre vider retirer la partie sup rieure Acette in ouvrir les fermetures lat ra...

Страница 17: ...20 240 Puissance nominale Watt 1200 1200 Puissance maxi Watt 1400 1400 Fr quence Hertz Hz 50 60 50 60 Courant d air m h MG 220 220 D pression hPa MG 248 248 Courant d air m h SE D pression hPa SE Pres...

Страница 18: ...caso contrario esiste il pericolo d incendio e di esplosione Pericolo Utilizzare la presa sull aspiratore solo per gli impieghi previsti nelle istruzioni d uso In caso di uso non conforme alla destina...

Страница 19: ...rico in uso R Funzione di pulizia iltro con l interruttore in questa posizione si mette in esercizio per ca 10 sec Il vibratore che poi si spegne automaticamente RA Stand by come A plus Pulizia iltro...

Страница 20: ...o di carta Estrarre con precauzione la langia dal bocchettone di aspirazi one e chiuderla Prima di riporre l aspiratore accendere il motore per consentire l aspirazione di eventuali polveri in sospens...

Страница 21: ...sima Watt 1400 1400 Frequenza Hertz Hz 50 60 50 60 Flusso d aria m h MG 220 220 Depressione hPa MG 248 248 Flusso d aria m h SE Depressione hPa SE Pressione ac stica dB A 69 5 69 5 l x b x h cm 45 7 x...

Страница 22: ...gsmittel mit L sungsmittel getr nktes Gut explosionsgef hrliche St u be Fl ssigkeiten wie Benzin l Alkohol Verd nnung oder Gut das hei er als 60 C ist aufgesaugt werden Es besteht sonst Explosions und...

Страница 23: ...schaltet danach automatisch aus RA Bereitschaftsbetrieb wie A plus automatische Filterabre nigung Die Steckdose b ist f r denAnschluss eines Elektrowerkzeugs vorgesehen Achtung Elektrowerkzeug muss b...

Страница 24: ...en gesetzlichen Bestimmungen entsorgen 6 Reinigung Beh lter und Zubeh r mit Wasser reinigen Oberteil mit feuch tem Tuch abwischen Beh lter und Zubeh r trocknen lassen 7 Wartung L sst die Saugleistung...

Страница 25: ...k dB A 69 5 69 5 l x b x h cm 45 7 x 40 x 54 58 7 x 47 x 64 Gewicht kg 12 7 17 7 Angegeben Lebensdauer Jahr 7 7 am Gebl se am Schlauch Anschlussleitung bei Ger ten mit Steckdose H05V V F 3x1 5 11 Gara...

Страница 26: ...e nem produtos a uma temperatura superior a 60 C H perigo de explos o e inc ndio Perigo Utilize a tomada no aspirador apenas para os ins estabeleci dos no manual de instru es O fabricante n o assume q...

Страница 27: ...amenta el ctrica R Fun o de limpeza do iltro nesta posi o de comuta o o vibrador ser colocado em funcionamento por aprox 10 s e desligar a seguir automaticamente RA Accionamento de prontid o para o fu...

Страница 28: ...sobre a abertura de aspira o 5 5 2 Troca do saco de iltro de papel Extrair o lange cuidadosamente da tubulatura de aspira o e fechar o lange Ligar o motor antes de depositar para que possa ser aspira...

Страница 29: ...Subpress o hPa MG 248 248 Corrente de ar m h SE Subpress o hPa SE Press o sonora dB A 69 5 69 5 l x b x h cm 45 7 x 40 x 54 58 7 x 47 x 64 Peso kg 12 7 17 7 no ventilador na mangueira Condutor de alim...

Страница 30: ...29 VC25 1400 VC50 1400 2006 42 EG EMV 2004 108 EG EN 12100 1 EN 12100 2 EN 60335 1 EN 60335 2 69 EN 55014 1 EN 55014 2 EN 61000 3 2 DIN EN 60335 1 DIN EN 60335 2 69 1 VC25 1400 VC50 1400 H 60 He...

Страница 31: ...30 2 3 4 2a 4 1 4 1 0 I A R 10 RA b 0 16A d 5 5 1...

Страница 32: ...31 5 2 5 4 5 3 5 3 1 R RA 5 3 2 a RA 5 4 1 a 5 5 5 5 1 25 50 5 5 2 4 6 7 90...

Страница 33: ...40 80 9 10 VC25 1400 VC50 1400 220 240 220 240 1200 1200 1400 1400 50 60 50 60 3 MG 220 220 M 248 248 3 SE 140 140 SE 225 225 69 5 69 5 l x b x h cm 45 7 40 54 58 7 47 64 12 7 17 7 7 7 H05V V F 3 x 1...

Страница 34: ...33 12 13 FELISATTI www felisatti es www felisatti eu...

Страница 35: ...34...

Страница 36: ...35...

Страница 37: ...IP24 ELECTROSTAR GmbH D 73262 Reichenbach Fils Germany E Mail info starmix de www starmix de bbn 40112408...

Отзывы: