11
5. EMERGENCY SITUATIONS
Felicity cannot guarantee eStrong battery absolute safety.
5.1 Fire
In case of
fi
res, make sure that the following equipment is available near the system.
• SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on Personal
Protective Equipment 89/686/EEC.
• NOVEC 1230, FM-200, or dioxide extinguisher
Batteries may explode when heated above 150°C. KEEP FAR AWAY from the battery if it catches
fi
re.
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed the leaked
substance, immediately perform the cations described below.
• Inhalation: Evacuate the contaminated area, and seek medical attention.
• Contact with eyes: Rinse eyes with running water for 5 minutes, and seek medical attention.
• Contact with skin: Wash the a
ff
ected area thoroughly with soap and water, and seek medical attention.
• Ingestion: Induce vomiting, and seek medical attention.
If the battery pack is wet or submerged in water, do not let people access it, and contact your supplier for help.
Damaged Batteries
Damaged batteries are not
fi
t for use and are dangerous and must be handled with the utmost care. It may
leak electrolyte or produce
fl
ammable gas. If the battery pack seems to be damaged, pack it in its original
container, and then return it to your supplier.
Products that are operated strictly in accordance with the user manual are covered by the warranty. Any
violation of this manual may void the warranty.
Limitation of Liability
Any product damage or property loss caused by the following conditions, Felicity does not assume any direct
or indirect liability.
• Product modi
fi
ed, design changed or parts replaced.
• Changed, or attempted repairs and erasing of series number or seals;
• System design and installation are not in compliance with standards and regulations;
• The product has been improperly stored in end user’s premises;
• Transport damage (including painting scratch caused by movement inside packaging during shipping). A
claim should be made directly to shipping or insurance company.
5.2 Leaking Batteries
5.3 Wet Batteries
5.4 Warranty
4.3 ON / OFF or SOC Led (Mode or SOC)
BATTERY
MODE
ON /OFF
SOC
REMARK
GREEN
LED RED
LED
LED1
LED2
LED3
LED4
POWER
OFF
OFF
OFF
OFF
OFF
OFF
OFF
POWER
ON
OFF
ON
ON
ON
ON
ON
STANDB Y
OFF
OFF
SOC
SOC< 10%(DEFAULT):
LED1
FLASH
NORMAL
ON
OFF
RUNNING /SOC
SOC< 10%(DEFAULT):
LED1
FLASH
DISCHAR GE
ON
OFF
SOC
SOC< 10%(DEFAULT):
LED1
FLASH
CHAR GE
FLASH
OFF
RUNNING
LOW
POWER
FLASH
OFF
OFF
FAULT
OFF
ON
ON
OFF
OFF
OFF BATTERY
VOLTAGE
HIGH
OFF
ON
OFF
OFF BATTERY
VOLTAGE
LOW
ON
ON
OFF
OFF CELL
VOLTAGE
HIGH
OFF
OFF
ON
OFF CELL
VOLTAGE
LOW
ON
OFF
ON
OFF CHAR GING
CURRENT
HIGH
OFF
ON
ON
OFF DISCHAR GING
CURRENT
HIGH
ON
ON
ON
OFF BMS
TEMPERATURE
HIGH
OFF
OFF
OFF
ON BMS
TEMPERATURE
LOW
ON
OFF
OFF
ON CELL
TEMPERATURE
HIGH
OFF
ON
OFF
ON CELL
TEMPERATURE
LOW
ON
ON
OFF
ON CURRENT
SENSOR
ABNOMAL
Sw1 SW2 SW3 SW4 Remarks
0 0 0 0 means ID=0,communication address is0x00/0x10
③
1 0 0 0 means ID=1,communication address is0x01
④
0 1 0 0 means ID=2,communication address is0x02
1 1 0 0 means ID=3,communication address is0x03
0 0 1 0 means ID=4,communication address is0x04
1 0 1 0 means ID=5,communication address is0x05
0 1 1 0 means ID=6,communication address is0x06
1 1 1 0 means ID=7,communication address is0x07
0 0 0 1 means ID=8,communication address is0x08
1 0 0 1 means ID=9,communication address is0x09
0 1 0 1 means ID=10,communication address is0x0A
1 1 0 1 means ID=11,communication address is0x0B
0 0 1 1 means ID=12,communication address is0x0C
1 0 1 1 means ID=13,communication address is0x0D
0 1 1 1 means ID=14,communication address is0x0E
1 1 1 1 means ID=15,communication address is0x0F
DIP switch SW5 Description
②
SW5
1
0
Remarks
means disconnect
120
Ω
resistor
means connect
120
Ω
resistor
Remark
①
: 1 in SW1-SW5 indicates ON status, and 0 indicates OFF status.
Remark
②
: When multiple battery packs communicate, the last battery pack SW5 needs to be in the ON
status, otherwise the communication may have interference.
Remark
③
: When the battery pack ID is set to 0, it means stand-alone operation, and it is not necessary to
detect whether the parallel condition is satis
fi
ed
⑤
Remark
④
: When the battery pack ID is set to 1-15, it means that the parallel operation is required, and it is
necessary to detect whether the parallel condition is satis
fi
ed
⑤
Remark
⑤
: The parallel condition is that the di
ff
erence between the battery voltage of the local battery and
all the battery pack voltages is <3V, otherwise wait until the condition is satis
fi
ed
DIP switch SW1-SW4 Description