KBM 52 U / KBM 50 Q
17
EN
15 Adapter for geared drill chuck with core drill
thread (M 18x6/P 1.5)
For clamping the twist drill and core drill
bits.
16 Adapter with securing nut (16b)
Adapter for Quick IN tool holder.
17 Use of spiral bits MK 3
18 Standard accessories
Adapter (M 18x6/P 1.5) (18c),
Geared drill chuck with drill-chuck
wrench (18d),
Long centering pin (119 mm) (18e),
Short centering pin (104 mm) (18f),
Chip hook (18g),
Drift (18h),
Clamping strap (18i),
Coolant container (18j),
Pump holder (18k),
Coolant tube (18l),
Power tool carry case, plastic (18m).
Only part of the accessories described or shown
in this instruction manual will be included with
your power tool.
For all the parts applicable for your power tool,
please see the spare parts list.
Intended use of the power tool.
This power tool is intended for commercial use
as a core drill for drilling materials with a mag-
netizable surface using core drill bits or twist
drill bits, and for reaming, countersinking and
tapping in a weather-protected environment
using the application tools and accessories rec-
ommended by FEIN.
The power tool can be used horizontally, verti-
cally or overhead.
Instructions for putting into
operation.
Please make sure that the contacting surface for
the magnetic foot is level, clean and rust-free.
Remove any varnish or primer.
When working on materials that are not mag-
netizable, suitable fixation devices, obtainable as
accessories from FEIN, e. g. suction plate, vac-
uum plate or pipe-drilling device must be used.
When work on steel materials with a material
thickness of less than 12 mm, the workpiece
must be reinforced with an additional steel plate
in order to guarantee the magnetic holding
power.
Mounting the guard protecting against
chippings and accidental contact (Figure 6).
The guard protecting against chippings and
accidental contact must always be mounted
during operation.
➤
Mount the guard protecting against chip-
pings and accidental contact (6).
➤
To remove any accumulated chippings,
open the guard protecting against chip-
pings and accidental contact (6).
➤
Before commencing operation, fasten
the guard protecting against chippings and
accidental contact (6) with the hook (6a).
Mounting the coolant container
(Figures 1 + 8 + 12).
➤
Place the filled coolant container (1) into
the holder provided on the motor housing.
Only use cooling lubricant that is capable of
being pumped.
➤
Fasten the coolant container (1) using
the fixation screw (8).
➤
Connect the coolant tube (18l).
3 41 01 063 06 0.book Seite 17 Donnerstag, 12. Mai 2005 8:42 08