background image

18

KBM 52 U / KBM 50 Q

EN

Operating instructions.

Adjustments.

Set the stroke range (Figure 13).

For changing the tool easily and fast, the setting 
of the stroke range is infinitely variable.

Loosen the lever (13) and set to the 

required stroke range.

Before commencing operation, tighten 

the lever (13) firmly again.

Changing the tool.

Core bit (Figure 14).

Push the centering pin (18e) through the 

core bit.

Turn the Quick IN clamping collar (14) 

of the tool holder anti-clockwise and insert 
the core bit with the centering pin.

Let go of the Quick IN clamping col-

lar (14) and turn the core bit in the tool 
holder until the catch notches.

Twist drill and core drill bits with M 18x6/P 1.5 
(Figure 15).

Screw the adapter (15) onto the geared 

drill chuck.

Turn the Quick IN clamping collar (14) 

of the tool holder anti-clockwise and insert 
the adapter (15) in the same way as the 
core bit.

The adapter can also be used for suitable core 
bits.

Twist drill bit with morse taper arbor
(KBM 52 U, Figures 16 + 17).

Loosen the securing nut (16b) of the 

tool holder. The securing nut has a left-
handed thread.

Knock the adapter (16) out using the 

drift (18h).

Clean the inner taper of the drift shaft 

and insert the MK 3 spiral bit (17).

General operating instructions.

Selecting the gear level (Figure 7).

Set the gear level to setting “

I

” for operations 

requiring a low speed and a high torque. This 
setting is suitable for drilling with large drilling 
diameters (26 mm–50 mm) and for tapping.
Set the gear level to setting “

II

” for operations 

requiring a high speed and a low torque. This 
setting is suitable for drilling with small drilling 
diameters (12 mm–26 mm).
Only switch over the gear level when the motor 
is at a standstill.

Putting into operation.

First check that the mains supply lead and 
mains plug are not damaged.

Secure the power tool with the clamping 
strap (18i) if there is danger of it falling.

KBM 52 U:

 

Note: 

If permissible, open the coolant 

stopcock (12).

Switch on the main (magnet) switch (11) 

for the magnet to clamp and hold the core 
drill.

Starting and stopping the motor (KBM 52 U):

Starting the motor in clockwise rotation, full 
speed:

Briefly tap the “

R

” on the motor 

switch (9) (clockwise rotation).

Stopping the motor during clockwise rotation:

Briefly tap “

L/OFF

” on the motor 

switch (9).

Starting the motor in anti-clockwise rotation:

Continuously press “

L/OFF

” (anti-clock-

wise rotation) on the motor switch (9).

Stopping the motor during anti-clockwise rota-
tion:

Let go of the motor switch (9).

Starting and stopping the motor (KBM 50 Q):

Starting:

Switch on the motor switch (9).

Stopping:

Switch off the motor switch (9).

3 41 01 063 06 0.book  Seite 18  Donnerstag, 12. Mai 2005  8:42 08

Содержание KBM 52 U

Страница 1: ...Y 2006 06Z DE EN 61029 EN 55014 EN 61000 3 2 EN 61000 3 3 98 37 EG 89 336 EWG ammersdorf uality Manager Dr Schreiber Manager of R D department EIN Service E FEIN GmbH ans Fein Stra e 81 73529 Schw bis...

Страница 2: ...___ _________________ Dansk ______________ Brugsanvisning___________________ Norsk ______________ Bruksanvisning___________________ Svenska ____________ Bruksanvisning___________________ Suomi _______...

Страница 3: ...3 4 2 3 6 5 1 6 a 3 41 01 063 06 0 book Seite 3 Donnerstag 12 Mai 2005 8 42 08...

Страница 4: ...4 12 8 KBM 52 U KBM 52 U KBM 50 Q 7 9 9 13 10 11 3 41 01 063 06 0 book Seite 4 Donnerstag 12 Mai 2005 8 42 08...

Страница 5: ...5 j l m c e f g i h 18 15 b 16 KBM 52 U KBM 52 U 14 17 d k j 3 41 01 063 06 0 book Seite 5 Donnerstag 12 Mai 2005 8 42 08...

Страница 6: ...is danger of it falling General mandatory sign Follow the instructions in the adjacent text Read documentation Be absolutely sure to read the enclosed documen tation such as the Instruction Manual an...

Страница 7: ...ign warns of a possible dangerous situation that could cause injury It is forbidden to dispose of the product in the unsorted household waste Worn out power tools and other electrotechnical and electr...

Страница 8: ...intensity noise may cause loss of hearing Do not use accessories which are not specifically designed and recommended by the power tool manufacturer Safe operation is not ensured merely because an acc...

Страница 9: ...putting into operation Please make sure that the contacting surface for the magnetic foot is level clean and rust free Remove any varnish or primer When working on materials that are not mag netizable...

Страница 10: ...structions Selecting the gear level Figure 7 Set the gear level to setting I for operations requiring a low speed and a high torque This setting is suitable for drilling with large drilling diameters...

Страница 11: ...is formed Do not stop the drill motor during the drilling procedure Only remove the core bit from of the drill ing hole while the motor is running If the core bit should remain stuck in the material s...

Страница 12: ...nce with the FEIN manufacturer s guar antee For further details on this please contact your specialist dealer your national FEIN repre sentative or the FEIN customer service centre Declaration of conf...

Страница 13: ...8 mm Stroke 135 mm 135 mm Total stroke range 310 mm 310 mm Magnetic foot plate dimensions 180 x 90 mm 180 x 90 mm Sound emission Measured A weighted sound power level LwA re 1 pW in decibels 96 96 Mea...